Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter

Introduction: Some reports have described superior vena cava isolation (SVCI) by the pentaspline pulsed-field ablation (PFA) catheter. However, this report presents a case series of superior vena cava (SVC) fibrillation successfully treated using a circular multielectrode array PFA catheter. Methods...

Full description

Saved in:
Bibliographic Details
Main Authors: Masatsugu Nozoe, MD, PhD, Hiroshi Mannoji, MD, PhD, Ryo Miyake, MD, Sayana Kuraoka, MD, Akihito Ishikita, MD, PhD, Nobuhiro Suematsu, MD, PhD, Toru Kubota, MD, PhD
Format: Article
Language:English
Published: Elsevier 2025-07-01
Series:JACC: Case Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2666084925006436
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849426100422180864
author Masatsugu Nozoe, MD, PhD
Hiroshi Mannoji, MD, PhD
Ryo Miyake, MD
Sayana Kuraoka, MD
Akihito Ishikita, MD, PhD
Nobuhiro Suematsu, MD, PhD
Toru Kubota, MD, PhD
author_facet Masatsugu Nozoe, MD, PhD
Hiroshi Mannoji, MD, PhD
Ryo Miyake, MD
Sayana Kuraoka, MD
Akihito Ishikita, MD, PhD
Nobuhiro Suematsu, MD, PhD
Toru Kubota, MD, PhD
author_sort Masatsugu Nozoe, MD, PhD
collection DOAJ
description Introduction: Some reports have described superior vena cava isolation (SVCI) by the pentaspline pulsed-field ablation (PFA) catheter. However, this report presents a case series of superior vena cava (SVC) fibrillation successfully treated using a circular multielectrode array PFA catheter. Methods: We performed SVCI using a PulseSelect PFA catheter (Medtronic) in 11 cases. SVCI was performed when the earliest activation during ectopy was inside the SVC. In the second session, SVCI was routinely performed if the myocardial sleeves were of sufficient length. Results: The mean number of PFA deliveries was 7.8 ± 2.1 applications. Short-term success of SVC isolation was achieved in all patients. Importantly, no cases of sinus node dysfunction or persistent phrenic nerve palsy were observed in this study. Conclusions: A circular multielectrode array PFA catheter is useful and safe for treating non–pulmonary vein foci triggered by the SVC.
format Article
id doaj-art-0fccbc87f7084513afde104d9dbdb8ea
institution Kabale University
issn 2666-0849
language English
publishDate 2025-07-01
publisher Elsevier
record_format Article
series JACC: Case Reports
spelling doaj-art-0fccbc87f7084513afde104d9dbdb8ea2025-08-20T03:29:34ZengElsevierJACC: Case Reports2666-08492025-07-01301710386510.1016/j.jaccas.2025.103865Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array CatheterMasatsugu Nozoe, MD, PhD0Hiroshi Mannoji, MD, PhD1Ryo Miyake, MD2Sayana Kuraoka, MD3Akihito Ishikita, MD, PhD4Nobuhiro Suematsu, MD, PhD5Toru Kubota, MD, PhD6Address for correspondence: Dr Masatsugu Nozoe, 1-3-46, Tenjin, Chuo-ku, Fukuoka 810-0001, Japan.; Division of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanDivision of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanDivision of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanDivision of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanDivision of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanDivision of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanDivision of Cardiology, Cardiovascular and Aortic Center, Saiseikai Fukuoka General Hospital, Fukuoka, JapanIntroduction: Some reports have described superior vena cava isolation (SVCI) by the pentaspline pulsed-field ablation (PFA) catheter. However, this report presents a case series of superior vena cava (SVC) fibrillation successfully treated using a circular multielectrode array PFA catheter. Methods: We performed SVCI using a PulseSelect PFA catheter (Medtronic) in 11 cases. SVCI was performed when the earliest activation during ectopy was inside the SVC. In the second session, SVCI was routinely performed if the myocardial sleeves were of sufficient length. Results: The mean number of PFA deliveries was 7.8 ± 2.1 applications. Short-term success of SVC isolation was achieved in all patients. Importantly, no cases of sinus node dysfunction or persistent phrenic nerve palsy were observed in this study. Conclusions: A circular multielectrode array PFA catheter is useful and safe for treating non–pulmonary vein foci triggered by the SVC.http://www.sciencedirect.com/science/article/pii/S2666084925006436atrial fibrillationnon–pulmonary vein focicircular multielectrode array catheterpulsed-field ablationsuperior vena cava
spellingShingle Masatsugu Nozoe, MD, PhD
Hiroshi Mannoji, MD, PhD
Ryo Miyake, MD
Sayana Kuraoka, MD
Akihito Ishikita, MD, PhD
Nobuhiro Suematsu, MD, PhD
Toru Kubota, MD, PhD
Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter
JACC: Case Reports
atrial fibrillation
non–pulmonary vein foci
circular multielectrode array catheter
pulsed-field ablation
superior vena cava
title Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter
title_full Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter
title_fullStr Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter
title_full_unstemmed Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter
title_short Successful Pulsed-Field Ablation of Superior Vena Cava Fibrillation Using a Circular Multielectrode Array Catheter
title_sort successful pulsed field ablation of superior vena cava fibrillation using a circular multielectrode array catheter
topic atrial fibrillation
non–pulmonary vein foci
circular multielectrode array catheter
pulsed-field ablation
superior vena cava
url http://www.sciencedirect.com/science/article/pii/S2666084925006436
work_keys_str_mv AT masatsugunozoemdphd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter
AT hiroshimannojimdphd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter
AT ryomiyakemd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter
AT sayanakuraokamd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter
AT akihitoishikitamdphd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter
AT nobuhirosuematsumdphd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter
AT torukubotamdphd successfulpulsedfieldablationofsuperiorvenacavafibrillationusingacircularmultielectrodearraycatheter