In Vitro and In Silico Analysis of Entrainment Characterization in Injection Jet-Assisted Fontan Circulation

Fontan circulation is a fragile system in which imperfections at any of multiple levels may compromise the quality of life, produce secondary pathophysiology, and shorten life span. Increased inferior vena caval pressure itself may play a role in “Fontan failure”. This study describes a mock flow lo...

Full description

Saved in:
Bibliographic Details
Main Authors: Arka Das, Ray O. Prather, Anthony Damon, Michael Farias, Alain Kassab, Eduardo Divo, William DeCampli
Format: Article
Language:English
Published: MDPI AG 2025-05-01
Series:Bioengineering
Subjects:
Online Access:https://www.mdpi.com/2306-5354/12/5/555
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Fontan circulation is a fragile system in which imperfections at any of multiple levels may compromise the quality of life, produce secondary pathophysiology, and shorten life span. Increased inferior vena caval pressure itself may play a role in “Fontan failure”. This study describes a mock flow loop model (MFL) designed to quantitatively estimate pulmonary flow entrainment induced by continuous and pulsed flow injections. A patient generic 3D-printed phantom model of the total cavopulmonary connection (TCPC) with average dimensions matching those of a 2–4-year-old patient was inserted in an MFL derived from a reduced lumped parameter model (LPM) representing cardiovascular circulation. The LPM comprises four 2-element Windkessel compartments (compliance and resistance), approximating the upper and lower systemic circulations and the right and left pulmonary circulations. The prescribed cardiac output is about 2.3 L/min for a body surface area of <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><mn>0.675</mn><msup><mrow><mrow><mo> </mo><mi mathvariant="normal">m</mi></mrow></mrow><mn>2</mn></msup></mrow></semantics></math></inline-formula>. The injections originate from an external pump through a 7–9 fr catheter, following a strict protocol suggested by the clinical team, featuring a variation in injection rate (flow rate), injection volume, and injection modality (continuous or pulsed). The key measurements in this study are the flow rates sampled at the distal pulmonary arteries, as well as at the upper and lower body boundaries. These measurements were then used to calculate effective entrainment as the difference between the measured and expected flow rates, as well as jet relaxation (rise and fall time of injection). The results show that for continuous or pulsed injections, varying the total volume injected has no significant influence on the entrainment rate across all injection rates. On the other hand, for both injection modalities, increasing the injection rate results in a reduction in entrainment that is consistent across all injected volumes. This study demonstrates the effectiveness of a high-speed injection jet entraining a slow co-flow while determining the potential for fluid buildup, which could ultimately cause an increase in caval pressure. To avoid the increase in caval pressure due to mass accumulation, we added a fenestration to our proposed injection jet shunt-assisted Fontan models. It was found that for a set of well-defined parameters, the jet not only can be beneficial to the local flow, but any adverse effect can be obviated by careful tuning. These results were also cross-validated with similar in silico findings.
ISSN:2306-5354