Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway

The overhead contact system of the electrification railway is exposed to the natural environment throughout the year and is liable to encounter the problem of line icing. The icing on the line will reduce the current-collection performance of the pantograph, resulting in a decrease in the safety and...

Full description

Saved in:
Bibliographic Details
Main Authors: Guosheng Huang, Mingli Wu, Jieyi Liang, Songping Fu, Fuqiang Tian, Xiaojuan Pei, Qiujiang Liu, Teng Li
Format: Article
Language:English
Published: MDPI AG 2025-02-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/5/1028
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850226145351434240
author Guosheng Huang
Mingli Wu
Jieyi Liang
Songping Fu
Fuqiang Tian
Xiaojuan Pei
Qiujiang Liu
Teng Li
author_facet Guosheng Huang
Mingli Wu
Jieyi Liang
Songping Fu
Fuqiang Tian
Xiaojuan Pei
Qiujiang Liu
Teng Li
author_sort Guosheng Huang
collection DOAJ
description The overhead contact system of the electrification railway is exposed to the natural environment throughout the year and is liable to encounter the problem of line icing. The icing on the line will reduce the current-collection performance of the pantograph, resulting in a decrease in the safety and reliability of the overhead contact system. It is an effective way to solve the icing problem by using the Joule heat generated by the DC in the conductor to melt the ice. In this paper, the multi-physics simulation software COMSOL is used to construct the finite element simulation model of the overhead contact system unit composed of a contact line, catenary wire and dropper. The model covers the physical processes such as convective heat transfer between conductor and air, heat conduction between overhead contact system and ice layer during ice melting, and considers the latent heat factor of ice melting. Under the condition of no icing, the actual data of several temperature points are measured under the applied current state of the overhead contact system, and the validity of the model is verified by comparing the simulated temperature data with the measured data. On this basis, the effects of ambient temperature, ice thickness and current on ice melting were studied using simulations. The results show that the ambient temperature has a significant effect on the ice-melting speed. Under 10 mm ice thickness and 2 m/s wind speed conditions, the time to start melting ice increases from 2 to 60 min until the ice cannot be melted as the ambient temperature decreases from −1 °C to −25 °C. Various initial conditions for ice thickness and wind speed were analyzed. Under the condition of no ice, the temperature rise of the contact wire and the catenary wire increases significantly with the current increase. When the current increases from 500 A to 2000 A, the temperature rise of the contact wire increases from 9.08–9.25 °C to 214.07–218.59 °C, and the temperature rise of the catenary wire increases from 6.88–7.01 °C to 173.43–177.13 °C. In addition, there is an optimal ice thickness range for the ice-melting process. When melting ice at −1 °C and −5 °C, the optimal ice thickness ranges are 4–8 mm and 1–4 mm, respectively.
format Article
id doaj-art-0d373b35fe274dddae2110a779acf9bd
institution OA Journals
issn 1996-1073
language English
publishDate 2025-02-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj-art-0d373b35fe274dddae2110a779acf9bd2025-08-20T02:05:09ZengMDPI AGEnergies1996-10732025-02-01185102810.3390/en18051028Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification RailwayGuosheng Huang0Mingli Wu1Jieyi Liang2Songping Fu3Fuqiang Tian4Xiaojuan Pei5Qiujiang Liu6Teng Li7School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaChina Railway Construction Electrification Bureau Group Co., Ltd., Beijing 100043, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaChina (Beijing) Railway Construction Electrification Design & Research Institute Co., Ltd., Beijing 100043, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaSchool of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, ChinaThe overhead contact system of the electrification railway is exposed to the natural environment throughout the year and is liable to encounter the problem of line icing. The icing on the line will reduce the current-collection performance of the pantograph, resulting in a decrease in the safety and reliability of the overhead contact system. It is an effective way to solve the icing problem by using the Joule heat generated by the DC in the conductor to melt the ice. In this paper, the multi-physics simulation software COMSOL is used to construct the finite element simulation model of the overhead contact system unit composed of a contact line, catenary wire and dropper. The model covers the physical processes such as convective heat transfer between conductor and air, heat conduction between overhead contact system and ice layer during ice melting, and considers the latent heat factor of ice melting. Under the condition of no icing, the actual data of several temperature points are measured under the applied current state of the overhead contact system, and the validity of the model is verified by comparing the simulated temperature data with the measured data. On this basis, the effects of ambient temperature, ice thickness and current on ice melting were studied using simulations. The results show that the ambient temperature has a significant effect on the ice-melting speed. Under 10 mm ice thickness and 2 m/s wind speed conditions, the time to start melting ice increases from 2 to 60 min until the ice cannot be melted as the ambient temperature decreases from −1 °C to −25 °C. Various initial conditions for ice thickness and wind speed were analyzed. Under the condition of no ice, the temperature rise of the contact wire and the catenary wire increases significantly with the current increase. When the current increases from 500 A to 2000 A, the temperature rise of the contact wire increases from 9.08–9.25 °C to 214.07–218.59 °C, and the temperature rise of the catenary wire increases from 6.88–7.01 °C to 173.43–177.13 °C. In addition, there is an optimal ice thickness range for the ice-melting process. When melting ice at −1 °C and −5 °C, the optimal ice thickness ranges are 4–8 mm and 1–4 mm, respectively.https://www.mdpi.com/1996-1073/18/5/1028DC ice meltingfinite element modelice-melting modeloverhead contact systems
spellingShingle Guosheng Huang
Mingli Wu
Jieyi Liang
Songping Fu
Fuqiang Tian
Xiaojuan Pei
Qiujiang Liu
Teng Li
Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway
Energies
DC ice melting
finite element model
ice-melting model
overhead contact systems
title Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway
title_full Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway
title_fullStr Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway
title_full_unstemmed Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway
title_short Research on the DC Ice-Melting Model and Its Influencing Factors on the Overhead Contact Systems of an Electrification Railway
title_sort research on the dc ice melting model and its influencing factors on the overhead contact systems of an electrification railway
topic DC ice melting
finite element model
ice-melting model
overhead contact systems
url https://www.mdpi.com/1996-1073/18/5/1028
work_keys_str_mv AT guoshenghuang researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT mingliwu researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT jieyiliang researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT songpingfu researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT fuqiangtian researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT xiaojuanpei researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT qiujiangliu researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway
AT tengli researchonthedcicemeltingmodelanditsinfluencingfactorsontheoverheadcontactsystemsofanelectrificationrailway