Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System

<p>The purpose of this study is to investigate the impacts of added filtration on the contrast-detail detectability of a digital X-ray imaging system for small animal studies. A digital X-ray imaging system specifically designed for small animal studies was used. This system is equipped with a...

Full description

Saved in:
Bibliographic Details
Format: Article
Language:English
Published: Wiley 2006-01-01
Series:International Journal of Biomedical Imaging
Online Access:http://www.hindawi.com/GetArticle.aspx?doi=10.1155/IJBI/2006/95754
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832568264488648704
collection DOAJ
description <p>The purpose of this study is to investigate the impacts of added filtration on the contrast-detail detectability of a digital X-ray imaging system for small animal studies. A digital X-ray imaging system specifically designed for small animal studies was used. This system is equipped with a micro X-ray source with a tungsten target and a beryllium window filtration and a CCD-based digital detector. Molybdenum filters of <mml:math> <mml:mn>0</mml:mn> </mml:math> mm, <mml:math> <mml:mn>0.02</mml:mn> </mml:math> mm, and <mml:math> <mml:mn>0.05</mml:mn> </mml:math> mm in thickness were added. The corresponding X-ray spectra and contrast-detail detectabilities were measured using two phantoms of different thicknesses simulating breast tissue under different exposures. The added Mo filters reduced the low-energy as well as the high-energy photons, hence providing a narrowband for imaging quality improvement. In the experiments with a <mml:math> <mml:mn>1.15</mml:mn> </mml:math> cm phantom, the optimal image detectability was observed using <mml:math> <mml:mn>22</mml:mn> </mml:math> kVp and the <mml:math> <mml:mn>0.05</mml:mn> </mml:math> mm Mo filter. With the <mml:math> <mml:mn>2.15</mml:mn> </mml:math> cm phantom, the best detectability was obtained with <mml:math> <mml:mn>22</mml:mn> </mml:math> kVp and the <mml:math> <mml:mn>0.02</mml:mn> </mml:math> mm Mo filter. Our experiments showed that appropriate filtrations could reduce certain low- and high-energy components of X-ray spectra which have limited contributions to image contrast. At the same time, such filtration could improve the contrast-detail detectability, particularly at relatively low kVp and high filtration. Therefore, optimal image quality can be obtained with the same absorbed radiation dose by the subjects when appropriate filtration is used.</p>
format Article
id doaj-art-0cdd0866ab274bcfb02111602517400d
institution Kabale University
issn 1687-4188
language English
publishDate 2006-01-01
publisher Wiley
record_format Article
series International Journal of Biomedical Imaging
spelling doaj-art-0cdd0866ab274bcfb02111602517400d2025-02-03T00:59:20ZengWileyInternational Journal of Biomedical Imaging1687-41882006-01-012006Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System<p>The purpose of this study is to investigate the impacts of added filtration on the contrast-detail detectability of a digital X-ray imaging system for small animal studies. A digital X-ray imaging system specifically designed for small animal studies was used. This system is equipped with a micro X-ray source with a tungsten target and a beryllium window filtration and a CCD-based digital detector. Molybdenum filters of <mml:math> <mml:mn>0</mml:mn> </mml:math> mm, <mml:math> <mml:mn>0.02</mml:mn> </mml:math> mm, and <mml:math> <mml:mn>0.05</mml:mn> </mml:math> mm in thickness were added. The corresponding X-ray spectra and contrast-detail detectabilities were measured using two phantoms of different thicknesses simulating breast tissue under different exposures. The added Mo filters reduced the low-energy as well as the high-energy photons, hence providing a narrowband for imaging quality improvement. In the experiments with a <mml:math> <mml:mn>1.15</mml:mn> </mml:math> cm phantom, the optimal image detectability was observed using <mml:math> <mml:mn>22</mml:mn> </mml:math> kVp and the <mml:math> <mml:mn>0.05</mml:mn> </mml:math> mm Mo filter. With the <mml:math> <mml:mn>2.15</mml:mn> </mml:math> cm phantom, the best detectability was obtained with <mml:math> <mml:mn>22</mml:mn> </mml:math> kVp and the <mml:math> <mml:mn>0.02</mml:mn> </mml:math> mm Mo filter. Our experiments showed that appropriate filtrations could reduce certain low- and high-energy components of X-ray spectra which have limited contributions to image contrast. At the same time, such filtration could improve the contrast-detail detectability, particularly at relatively low kVp and high filtration. Therefore, optimal image quality can be obtained with the same absorbed radiation dose by the subjects when appropriate filtration is used.</p>http://www.hindawi.com/GetArticle.aspx?doi=10.1155/IJBI/2006/95754
spellingShingle Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System
International Journal of Biomedical Imaging
title Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System
title_full Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System
title_fullStr Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System
title_full_unstemmed Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System
title_short Impacts of Filtration on Contrast-Detail Detectability of an X-ray Imaging System
title_sort impacts of filtration on contrast detail detectability of an x ray imaging system
url http://www.hindawi.com/GetArticle.aspx?doi=10.1155/IJBI/2006/95754