Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process
In this study, Fluent as a computational fluid dynamic software was used to simulate the process of unsteady heat conduction and convection of the air in an air - conditioning room during the start - up process of the air - conditioning instruments. On the basis of the flying- rising curves obtained...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Journal of Refrigeration Magazines Agency Co., Ltd.
2005-01-01
|
| Series: | Zhileng xuebao |
| Online Access: | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2005.03.004 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849705371031044096 |
|---|---|
| author | 张欢 宋国军 王志刚 李瑞新 李秋生 |
| author_facet | 张欢 宋国军 王志刚 李瑞新 李秋生 |
| author_sort | 张欢 |
| collection | DOAJ |
| description | In this study, Fluent as a computational fluid dynamic software was used to simulate the process of unsteady heat conduction and convection of the air in an air - conditioning room during the start - up process of the air - conditioning instruments. On the basis of the flying- rising curves obtained from the process of the simulation, a mathematics model established to reflect the dynamic response of the air in the air - conditioning room during the air - conditioning instruments starting up was analyzed and testified through start- up experiments under various out- door temperature. |
| format | Article |
| id | doaj-art-0c9b0f9cdcaf4cb28fef18439b803ba4 |
| institution | DOAJ |
| issn | 0253-4339 |
| language | zho |
| publishDate | 2005-01-01 |
| publisher | Journal of Refrigeration Magazines Agency Co., Ltd. |
| record_format | Article |
| series | Zhileng xuebao |
| spelling | doaj-art-0c9b0f9cdcaf4cb28fef18439b803ba42025-08-20T03:16:29ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392005-01-0166524271Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process张欢宋国军王志刚李瑞新李秋生In this study, Fluent as a computational fluid dynamic software was used to simulate the process of unsteady heat conduction and convection of the air in an air - conditioning room during the start - up process of the air - conditioning instruments. On the basis of the flying- rising curves obtained from the process of the simulation, a mathematics model established to reflect the dynamic response of the air in the air - conditioning room during the air - conditioning instruments starting up was analyzed and testified through start- up experiments under various out- door temperature.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2005.03.004 |
| spellingShingle | 张欢 宋国军 王志刚 李瑞新 李秋生 Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process Zhileng xuebao |
| title | Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process |
| title_full | Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process |
| title_fullStr | Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process |
| title_full_unstemmed | Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process |
| title_short | Research on Thermal Field Dynamic Response in Air- conditioning Room during Start- Up Process |
| title_sort | research on thermal field dynamic response in air conditioning room during start up process |
| url | http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2005.03.004 |
| work_keys_str_mv | AT zhānghuān researchonthermalfielddynamicresponseinairconditioningroomduringstartupprocess AT sòngguójūn researchonthermalfielddynamicresponseinairconditioningroomduringstartupprocess AT wángzhìgāng researchonthermalfielddynamicresponseinairconditioningroomduringstartupprocess AT lǐruìxīn researchonthermalfielddynamicresponseinairconditioningroomduringstartupprocess AT lǐqiūshēng researchonthermalfielddynamicresponseinairconditioningroomduringstartupprocess |