Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage

Abstract Background Neuroprotective measures to prevent secondary brain injury are a critical aspect of pre-hospital management in patients with acute traumatic brain injury (TBI) and spontaneous intracranial haemorrhage (sICH). Haemodynamic optimisation guided by non-invasive blood pressure (NIBP)...

Full description

Saved in:
Bibliographic Details
Main Authors: J. E. Griggs, S. Clarke, R. Greenhalgh, A. N. Watts, J. Barrett, S. Houghton Budd, M. Dias, K. Hunter, R. M. Lyon, E. ter Avest, On behalf of Air Ambulance Charity Kent Surrey Sussex
Format: Article
Language:English
Published: BMC 2025-05-01
Series:Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Subjects:
Online Access:https://doi.org/10.1186/s13049-025-01393-4
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850273348616978432
author J. E. Griggs
S. Clarke
R. Greenhalgh
A. N. Watts
J. Barrett
S. Houghton Budd
M. Dias
K. Hunter
R. M. Lyon
E. ter Avest
On behalf of Air Ambulance Charity Kent Surrey Sussex
author_facet J. E. Griggs
S. Clarke
R. Greenhalgh
A. N. Watts
J. Barrett
S. Houghton Budd
M. Dias
K. Hunter
R. M. Lyon
E. ter Avest
On behalf of Air Ambulance Charity Kent Surrey Sussex
author_sort J. E. Griggs
collection DOAJ
description Abstract Background Neuroprotective measures to prevent secondary brain injury are a critical aspect of pre-hospital management in patients with acute traumatic brain injury (TBI) and spontaneous intracranial haemorrhage (sICH). Haemodynamic optimisation guided by non-invasive blood pressure (NIBP) measurements is an important neuroprotective measure, as cerebral autoregulation is often absent or impaired. The accuracy and clinical relevance of invasive arterial blood pressure (IBP) monitoring to optimise haemodynamic management has not been established in patients with a brain insult. Methods A retrospective clinical diagnostic accuracy study to establish the accuracy and clinical relevance of IBP-guided haemodynamic optimisation in patients with TBI or sICH. The occurrence- and clinical relevance of IBP-NIBP discrepancies in patients attended by a UK Helicopter Emergency Medical Service (HEMS) between 6 January 2022 and 6 January 2024 was evaluated. Bland-Altman plots with adjustment for repeated measures were constructed to analyse disagreement in relation to absolute blood pressure values. Multivariate analysis was performed using generalised linear mixed effects regression (GLMER) models with random effects to identify predictors of disagreement. Error Grid Analysis (EGA) classified the clinical relevance of discrepancies. The primary outcome was pairwise agreement between IBP and NIBP, defined as less than 10% difference in mean arterial pressure (MAP). Results For 209 patients (159 TBI and 50 sICH) 1020 concurrent IBP and NIBP measurements were available. The average [95% CI] difference in MAP was -1.4 mmHg (-3.09 to 0.27) and 2.6mmHg in TBI. Only 459 (54.7%) MAP data met criteria for pairwise agreement. Multivariate regression analysis revealed a strong association between MAP disagreement and ground emergency medical service conveyance (aOR 2.01, 95% CI 0.98-4.10). Bland-Altman analysis demonstrated proportional bias, with NIBP underestimation of MAP at higher blood pressures and overestimation at lower blood pressures. EGA revealed that in 6.1% (95% CI: 4.5-7.7) of TBI and 12.5% (95% CI: 7.8-17.2) of patients with sICH pairwise disagreement was associated with a moderate to dangerous risk of over- or undertreatment. Conclusion NIBP guided pre-hospital haemodynamic management of patients with TBI or sICH is hampered by clinically relevant measurement inaccuracies in a significant proportion of patients. Pre-hospital IBP has the potential to improve early haemodynamic optimisation, especially when hypo- or hypertension is present, enabling tailored neuroprotection in the hyperacute phase.
format Article
id doaj-art-0c6b96b6e7f945d889adb2b86ef002bd
institution OA Journals
issn 1757-7241
language English
publishDate 2025-05-01
publisher BMC
record_format Article
series Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
spelling doaj-art-0c6b96b6e7f945d889adb2b86ef002bd2025-08-20T01:51:31ZengBMCScandinavian Journal of Trauma, Resuscitation and Emergency Medicine1757-72412025-05-0133111110.1186/s13049-025-01393-4Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhageJ. E. Griggs0S. Clarke1R. Greenhalgh2A. N. Watts3J. Barrett4S. Houghton Budd5M. Dias6K. Hunter7R. M. Lyon8E. ter Avest9On behalf of Air Ambulance Charity Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAir Ambulance Kent Surrey SussexAbstract Background Neuroprotective measures to prevent secondary brain injury are a critical aspect of pre-hospital management in patients with acute traumatic brain injury (TBI) and spontaneous intracranial haemorrhage (sICH). Haemodynamic optimisation guided by non-invasive blood pressure (NIBP) measurements is an important neuroprotective measure, as cerebral autoregulation is often absent or impaired. The accuracy and clinical relevance of invasive arterial blood pressure (IBP) monitoring to optimise haemodynamic management has not been established in patients with a brain insult. Methods A retrospective clinical diagnostic accuracy study to establish the accuracy and clinical relevance of IBP-guided haemodynamic optimisation in patients with TBI or sICH. The occurrence- and clinical relevance of IBP-NIBP discrepancies in patients attended by a UK Helicopter Emergency Medical Service (HEMS) between 6 January 2022 and 6 January 2024 was evaluated. Bland-Altman plots with adjustment for repeated measures were constructed to analyse disagreement in relation to absolute blood pressure values. Multivariate analysis was performed using generalised linear mixed effects regression (GLMER) models with random effects to identify predictors of disagreement. Error Grid Analysis (EGA) classified the clinical relevance of discrepancies. The primary outcome was pairwise agreement between IBP and NIBP, defined as less than 10% difference in mean arterial pressure (MAP). Results For 209 patients (159 TBI and 50 sICH) 1020 concurrent IBP and NIBP measurements were available. The average [95% CI] difference in MAP was -1.4 mmHg (-3.09 to 0.27) and 2.6mmHg in TBI. Only 459 (54.7%) MAP data met criteria for pairwise agreement. Multivariate regression analysis revealed a strong association between MAP disagreement and ground emergency medical service conveyance (aOR 2.01, 95% CI 0.98-4.10). Bland-Altman analysis demonstrated proportional bias, with NIBP underestimation of MAP at higher blood pressures and overestimation at lower blood pressures. EGA revealed that in 6.1% (95% CI: 4.5-7.7) of TBI and 12.5% (95% CI: 7.8-17.2) of patients with sICH pairwise disagreement was associated with a moderate to dangerous risk of over- or undertreatment. Conclusion NIBP guided pre-hospital haemodynamic management of patients with TBI or sICH is hampered by clinically relevant measurement inaccuracies in a significant proportion of patients. Pre-hospital IBP has the potential to improve early haemodynamic optimisation, especially when hypo- or hypertension is present, enabling tailored neuroprotection in the hyperacute phase.https://doi.org/10.1186/s13049-025-01393-4Pre-hospital emergency medicineTraumatic brain injurySpontaneous intracranial haemorrhageInvasive arterial blood pressureNon-invasive blood pressureNeuroprotection
spellingShingle J. E. Griggs
S. Clarke
R. Greenhalgh
A. N. Watts
J. Barrett
S. Houghton Budd
M. Dias
K. Hunter
R. M. Lyon
E. ter Avest
On behalf of Air Ambulance Charity Kent Surrey Sussex
Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Pre-hospital emergency medicine
Traumatic brain injury
Spontaneous intracranial haemorrhage
Invasive arterial blood pressure
Non-invasive blood pressure
Neuroprotection
title Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
title_full Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
title_fullStr Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
title_full_unstemmed Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
title_short Diagnostic accuracy of pre-hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
title_sort diagnostic accuracy of pre hospital invasive arterial blood pressure monitoring for haemodynamic management in traumatic brain injury and spontaneous intracranial haemorrhage
topic Pre-hospital emergency medicine
Traumatic brain injury
Spontaneous intracranial haemorrhage
Invasive arterial blood pressure
Non-invasive blood pressure
Neuroprotection
url https://doi.org/10.1186/s13049-025-01393-4
work_keys_str_mv AT jegriggs diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT sclarke diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT rgreenhalgh diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT anwatts diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT jbarrett diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT shoughtonbudd diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT mdias diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT khunter diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT rmlyon diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT eteravest diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage
AT onbehalfofairambulancecharitykentsurreysussex diagnosticaccuracyofprehospitalinvasivearterialbloodpressuremonitoringforhaemodynamicmanagementintraumaticbraininjuryandspontaneousintracranialhaemorrhage