An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
FDK algorithm is a well-known 3D (three-dimensional) approximate algorithm for CT (computed tomography) image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangen...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2006-01-01
|
Series: | International Journal of Biomedical Imaging |
Online Access: | http://dx.doi.org/10.1155/IJBI/2006/29370 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832549282200158208 |
---|---|
author | Ming Yan Cishen Zhang Hongzhu Liang |
author_facet | Ming Yan Cishen Zhang Hongzhu Liang |
author_sort | Ming Yan |
collection | DOAJ |
description | FDK algorithm is a well-known 3D (three-dimensional) approximate algorithm for CT (computed tomography) image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional) approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction. |
format | Article |
id | doaj-art-0af6c38d9ad14d568fb7aac848ab874a |
institution | Kabale University |
issn | 1687-4188 1687-4196 |
language | English |
publishDate | 2006-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Biomedical Imaging |
spelling | doaj-art-0af6c38d9ad14d568fb7aac848ab874a2025-02-03T06:11:33ZengWileyInternational Journal of Biomedical Imaging1687-41881687-41962006-01-01200610.1155/IJBI/2006/2937029370An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential FilteringMing Yan0Cishen Zhang1Hongzhu Liang2School of Electrical and Electronic Engineering, Nanyang Technological University, 639798, SingaporeSchool of Electrical and Electronic Engineering, Nanyang Technological University, 639798, SingaporeSchool of Electrical and Electronic Engineering, Nanyang Technological University, 639798, SingaporeFDK algorithm is a well-known 3D (three-dimensional) approximate algorithm for CT (computed tomography) image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional) approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction.http://dx.doi.org/10.1155/IJBI/2006/29370 |
spellingShingle | Ming Yan Cishen Zhang Hongzhu Liang An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering International Journal of Biomedical Imaging |
title | An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering |
title_full | An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering |
title_fullStr | An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering |
title_full_unstemmed | An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering |
title_short | An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering |
title_sort | approximate cone beam reconstruction algorithm for gantry tilted ct using tangential filtering |
url | http://dx.doi.org/10.1155/IJBI/2006/29370 |
work_keys_str_mv | AT mingyan anapproximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering AT cishenzhang anapproximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering AT hongzhuliang anapproximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering AT mingyan approximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering AT cishenzhang approximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering AT hongzhuliang approximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering |