An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering

FDK algorithm is a well-known 3D (three-dimensional) approximate algorithm for CT (computed tomography) image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangen...

Full description

Saved in:
Bibliographic Details
Main Authors: Ming Yan, Cishen Zhang, Hongzhu Liang
Format: Article
Language:English
Published: Wiley 2006-01-01
Series:International Journal of Biomedical Imaging
Online Access:http://dx.doi.org/10.1155/IJBI/2006/29370
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832549282200158208
author Ming Yan
Cishen Zhang
Hongzhu Liang
author_facet Ming Yan
Cishen Zhang
Hongzhu Liang
author_sort Ming Yan
collection DOAJ
description FDK algorithm is a well-known 3D (three-dimensional) approximate algorithm for CT (computed tomography) image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional) approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction.
format Article
id doaj-art-0af6c38d9ad14d568fb7aac848ab874a
institution Kabale University
issn 1687-4188
1687-4196
language English
publishDate 2006-01-01
publisher Wiley
record_format Article
series International Journal of Biomedical Imaging
spelling doaj-art-0af6c38d9ad14d568fb7aac848ab874a2025-02-03T06:11:33ZengWileyInternational Journal of Biomedical Imaging1687-41881687-41962006-01-01200610.1155/IJBI/2006/2937029370An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential FilteringMing Yan0Cishen Zhang1Hongzhu Liang2School of Electrical and Electronic Engineering, Nanyang Technological University, 639798, SingaporeSchool of Electrical and Electronic Engineering, Nanyang Technological University, 639798, SingaporeSchool of Electrical and Electronic Engineering, Nanyang Technological University, 639798, SingaporeFDK algorithm is a well-known 3D (three-dimensional) approximate algorithm for CT (computed tomography) image reconstruction and is also known to suffer from considerable artifacts when the scanning cone angle is large. Recently, it has been improved by performing the ramp filtering along the tangential direction of the X-ray source helix for dealing with the large cone angle problem. In this paper, we present an FDK-type approximate reconstruction algorithm for gantry-tilted CT imaging. The proposed method improves the image reconstruction by filtering the projection data along a proper direction which is determined by CT parameters and gantry-tilted angle. As a result, the proposed algorithm for gantry-tilted CT reconstruction can provide more scanning flexibilities in clinical CT scanning and is efficient in computation. The performance of the proposed algorithm is evaluated with turbell clock phantom and thorax phantom and compared with FDK algorithm and a popular 2D (two-dimensional) approximate algorithm. The results show that the proposed algorithm can achieve better image quality for gantry-tilted CT image reconstruction.http://dx.doi.org/10.1155/IJBI/2006/29370
spellingShingle Ming Yan
Cishen Zhang
Hongzhu Liang
An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
International Journal of Biomedical Imaging
title An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
title_full An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
title_fullStr An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
title_full_unstemmed An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
title_short An Approximate Cone Beam Reconstruction Algorithm for Gantry-Tilted CT Using Tangential Filtering
title_sort approximate cone beam reconstruction algorithm for gantry tilted ct using tangential filtering
url http://dx.doi.org/10.1155/IJBI/2006/29370
work_keys_str_mv AT mingyan anapproximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering
AT cishenzhang anapproximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering
AT hongzhuliang anapproximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering
AT mingyan approximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering
AT cishenzhang approximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering
AT hongzhuliang approximateconebeamreconstructionalgorithmforgantrytiltedctusingtangentialfiltering