Do the Microshear Test Variables Affect the Bond Strength Values?
Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (): polyethylene tube (3 levels) and adh...
Saved in:
Main Authors: | , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2012-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2012/618960 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832556723092586496 |
---|---|
author | Andrea M. Andrade Eugenio Garcia Sandra Kiss Moura Alessandra Reis Alessandro Loguercio Luciana Mendonça Silva Gustavo H. D. Pimentel Rosa Helena Miranda Grande |
author_facet | Andrea M. Andrade Eugenio Garcia Sandra Kiss Moura Alessandra Reis Alessandro Loguercio Luciana Mendonça Silva Gustavo H. D. Pimentel Rosa Helena Miranda Grande |
author_sort | Andrea M. Andrade |
collection | DOAJ |
description | Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey’s tests. Groups 1 and 2 resulted in statistically similar mean μSBS (); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values. |
format | Article |
id | doaj-art-0aa1b27df1704a609b8e2d222be48092 |
institution | Kabale University |
issn | 1687-8728 1687-8736 |
language | English |
publishDate | 2012-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Dentistry |
spelling | doaj-art-0aa1b27df1704a609b8e2d222be480922025-02-03T05:44:29ZengWileyInternational Journal of Dentistry1687-87281687-87362012-01-01201210.1155/2012/618960618960Do the Microshear Test Variables Affect the Bond Strength Values?Andrea M. Andrade0Eugenio Garcia1Sandra Kiss Moura2Alessandra Reis3Alessandro Loguercio4Luciana Mendonça Silva5Gustavo H. D. Pimentel6Rosa Helena Miranda Grande7Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, Cidade Universitária, 05508-000 São Paulo, SP, BrazilDepartment of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, Cidade Universitária, 05508-000 São Paulo, SP, BrazilDepartment of Restorative Dentistry, School of Dentistry, University of North of Parana, Rua Marselha 183, Jardim Piza, 86041-140 Londrina, PR, BrazilDepartment of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Avenue Carlos Cavalacanti 4748, Uvaranas, 84030-900 Ponta Grossa, PR, BrazilDepartment of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Avenue Carlos Cavalacanti 4748, Uvaranas, 84030-900 Ponta Grossa, PR, BrazilSchool of Dentistry, Federal University of Amazonas, Avenue Ministro Valdemar Pedrosa 1539, Centro, 69025-050 Manaus, AM, BrazilSchool of Dentistry, Federal University of Amazonas, Avenue Ministro Valdemar Pedrosa 1539, Centro, 69025-050 Manaus, AM, BrazilDepartment of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, Cidade Universitária, 05508-000 São Paulo, SP, BrazilLittle is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS) results. To evaluate whether variations in polyethylene rod use affect (μSBS)). Human dentin disks were randomly distributed into six groups (): polyethylene tube (3 levels) and adhesive system (2 levels). In Group 1, polyethylene tubes filled with polymerized composite) were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey’s tests. Groups 1 and 2 resulted in statistically similar mean μSBS (); however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (). Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values.http://dx.doi.org/10.1155/2012/618960 |
spellingShingle | Andrea M. Andrade Eugenio Garcia Sandra Kiss Moura Alessandra Reis Alessandro Loguercio Luciana Mendonça Silva Gustavo H. D. Pimentel Rosa Helena Miranda Grande Do the Microshear Test Variables Affect the Bond Strength Values? International Journal of Dentistry |
title | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_full | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_fullStr | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_full_unstemmed | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_short | Do the Microshear Test Variables Affect the Bond Strength Values? |
title_sort | do the microshear test variables affect the bond strength values |
url | http://dx.doi.org/10.1155/2012/618960 |
work_keys_str_mv | AT andreamandrade dothemicrosheartestvariablesaffectthebondstrengthvalues AT eugeniogarcia dothemicrosheartestvariablesaffectthebondstrengthvalues AT sandrakissmoura dothemicrosheartestvariablesaffectthebondstrengthvalues AT alessandrareis dothemicrosheartestvariablesaffectthebondstrengthvalues AT alessandrologuercio dothemicrosheartestvariablesaffectthebondstrengthvalues AT lucianamendoncasilva dothemicrosheartestvariablesaffectthebondstrengthvalues AT gustavohdpimentel dothemicrosheartestvariablesaffectthebondstrengthvalues AT rosahelenamirandagrande dothemicrosheartestvariablesaffectthebondstrengthvalues |