Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)

This study aimed at comparing shear-bond strength (SBS) of different self-etching adhesive systems (Clearfil S3 Bond Plus, G-Premio BOND and IBond) to dentin without or with diode-laser irradiation before photo-polymerization and to determine the effect of storage and thermo-cycling on SBS of adhesi...

Full description

Saved in:
Bibliographic Details
Main Authors: Wiaam M.O. AL-Ashou, Rajaa Taher, Alaa H. Ali
Format: Article
Language:English
Published: Springer 2022-12-01
Series:Saudi Dental Journal
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S1013905222001456
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849703034944225280
author Wiaam M.O. AL-Ashou
Rajaa Taher
Alaa H. Ali
author_facet Wiaam M.O. AL-Ashou
Rajaa Taher
Alaa H. Ali
author_sort Wiaam M.O. AL-Ashou
collection DOAJ
description This study aimed at comparing shear-bond strength (SBS) of different self-etching adhesive systems (Clearfil S3 Bond Plus, G-Premio BOND and IBond) to dentin without or with diode-laser irradiation before photo-polymerization and to determine the effect of storage and thermo-cycling on SBS of adhesive systems. Methods: The buccal surface of 84 extracted maxillary premolars was grounded to create flat surface. The specimens were allocated into 3 groups (n = 28) depending upon the adhesive systems, then each group was divided into two sub-group (I, II) (n = 14). After the placement of respective adhesive systems on the flat surface, adhesive system in group I was photo-polymerized immediately, while in group II, the adhesive systems were exposed to diode-laser before photo-polymerization. Composite cylinder (4 mm in diameter and 2 mm height) was built on the flat surface of each specimen. Then group I and II were divided into two sub-groups (n = 7) according to the storage time and thermo-cycling (1 day without thermo-cycling or 72 days with thermo-cycling) then all the specimens were stored in distilled water. The SBS was measured at the end of storage period. ANOVA, Duncan’s Multiple Range Test and independent t-test “P ≤ 0.05” were used for data analysis. Results: G-premio BOND showed the highest mean value of SBS followed by Clearfil S3 Bond plus without significant difference between them, while IBond revealed the least mean value. Laser irradiation had positive effect on the bond-strength of all tested adhesive systems. The results also showed that the storage with thermo-cycling had negative effect on the bond-strength in groups without laser irradiation for all tested adhesive systems, while for groups with laser irradiation, the reduction in the bond-strength of all tested adhesive systems was not significant. Conclusion: Diode-laser application prior to photo-polymerization of self-etch adhesive systems significantly increased the bond-strength to dentin and can increase the durability of composite adhesion.
format Article
id doaj-art-09c09b737ee141ae9f5f103be36dd48c
institution DOAJ
issn 1013-9052
language English
publishDate 2022-12-01
publisher Springer
record_format Article
series Saudi Dental Journal
spelling doaj-art-09c09b737ee141ae9f5f103be36dd48c2025-08-20T03:17:26ZengSpringerSaudi Dental Journal1013-90522022-12-0134877978710.1016/j.sdentj.2022.11.009Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)Wiaam M.O. AL-Ashou0Rajaa Taher1Alaa H. Ali2Corresponding author.; Department of Conservative Dentistry, College of Dentistry, University of Mosul, Mosul, IraqDepartment of Conservative Dentistry, College of Dentistry, University of Mosul, Mosul, IraqDepartment of Conservative Dentistry, College of Dentistry, University of Mosul, Mosul, IraqThis study aimed at comparing shear-bond strength (SBS) of different self-etching adhesive systems (Clearfil S3 Bond Plus, G-Premio BOND and IBond) to dentin without or with diode-laser irradiation before photo-polymerization and to determine the effect of storage and thermo-cycling on SBS of adhesive systems. Methods: The buccal surface of 84 extracted maxillary premolars was grounded to create flat surface. The specimens were allocated into 3 groups (n = 28) depending upon the adhesive systems, then each group was divided into two sub-group (I, II) (n = 14). After the placement of respective adhesive systems on the flat surface, adhesive system in group I was photo-polymerized immediately, while in group II, the adhesive systems were exposed to diode-laser before photo-polymerization. Composite cylinder (4 mm in diameter and 2 mm height) was built on the flat surface of each specimen. Then group I and II were divided into two sub-groups (n = 7) according to the storage time and thermo-cycling (1 day without thermo-cycling or 72 days with thermo-cycling) then all the specimens were stored in distilled water. The SBS was measured at the end of storage period. ANOVA, Duncan’s Multiple Range Test and independent t-test “P ≤ 0.05” were used for data analysis. Results: G-premio BOND showed the highest mean value of SBS followed by Clearfil S3 Bond plus without significant difference between them, while IBond revealed the least mean value. Laser irradiation had positive effect on the bond-strength of all tested adhesive systems. The results also showed that the storage with thermo-cycling had negative effect on the bond-strength in groups without laser irradiation for all tested adhesive systems, while for groups with laser irradiation, the reduction in the bond-strength of all tested adhesive systems was not significant. Conclusion: Diode-laser application prior to photo-polymerization of self-etch adhesive systems significantly increased the bond-strength to dentin and can increase the durability of composite adhesion.http://www.sciencedirect.com/science/article/pii/S1013905222001456Adhesive SystemDentinDiode laserShear Bond StrengthSelf-etch
spellingShingle Wiaam M.O. AL-Ashou
Rajaa Taher
Alaa H. Ali
Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)
Saudi Dental Journal
Adhesive System
Dentin
Diode laser
Shear Bond Strength
Self-etch
title Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)
title_full Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)
title_fullStr Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)
title_full_unstemmed Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)
title_short Shear-bond strength of different Self-Etching adhesive systems to dentin with or without laser irradiation before photopolymerization (A comparative Study)
title_sort shear bond strength of different self etching adhesive systems to dentin with or without laser irradiation before photopolymerization a comparative study
topic Adhesive System
Dentin
Diode laser
Shear Bond Strength
Self-etch
url http://www.sciencedirect.com/science/article/pii/S1013905222001456
work_keys_str_mv AT wiaammoalashou shearbondstrengthofdifferentselfetchingadhesivesystemstodentinwithorwithoutlaserirradiationbeforephotopolymerizationacomparativestudy
AT rajaataher shearbondstrengthofdifferentselfetchingadhesivesystemstodentinwithorwithoutlaserirradiationbeforephotopolymerizationacomparativestudy
AT alaahali shearbondstrengthofdifferentselfetchingadhesivesystemstodentinwithorwithoutlaserirradiationbeforephotopolymerizationacomparativestudy