A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin
Background: The rapidly increasing cases of noncommunicable diseases (NCDs) are required to be managed to maintain the sustainable development of society. HaemurEx, developed by Arogyam Medisoft Solution, is a battery-operated, lightweight, photometric clinical chemistry analyzer with the ability to...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Jaypee Brothers Medical Publisher
2023-12-01
|
| Series: | Indian Journal of Medical Biochemistry |
| Subjects: | |
| Online Access: | https://www.ijmb.in/doi/IJMB/pdf/10.5005/jp-journals-10054-0216 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850145408926351360 |
|---|---|
| author | Kusuma Kasapura Shivashankar Swetha Nagarahalli Kempegowda Abhijith Devaraju Akila Prashant Suma Maduvanahalli Nataraj Partha Chakraborty Amrita Mukherjee |
| author_facet | Kusuma Kasapura Shivashankar Swetha Nagarahalli Kempegowda Abhijith Devaraju Akila Prashant Suma Maduvanahalli Nataraj Partha Chakraborty Amrita Mukherjee |
| author_sort | Kusuma Kasapura Shivashankar |
| collection | DOAJ |
| description | Background: The rapidly increasing cases of noncommunicable diseases (NCDs) are required to be managed to maintain the sustainable development of society. HaemurEx, developed by Arogyam Medisoft Solution, is a battery-operated, lightweight, photometric clinical chemistry analyzer with the ability to transmit data to a remote health platform. It can evaluate different blood and urine biomarkers related to various NCDs and women’s health at the community level. This novel device can advance universal access to healthcare by enhancing the availability, accessibility, and affordability of testing the blood and urine biomarkers in primary health setup and thus can improve screening and monitoring of NCD conditions. The present study compares the results obtained from HaemurEx with the standard methodologies for patient care to determine its efficacy and accuracy.
Materials and methods: The amount of glucose, total cholesterol, triglyceride, total bilirubin, direct bilirubin, and creatinine were estimated in 40 blood samples collected from the inpatient and outpatient facilities at JSS Medical College, Mysuru, Karnataka, India using the standard methodologies. The same samples were analyzed on the same day using HaemurEx. The results obtained from both methods were compared to validate the performance characteristics of HaemurEx for its operation.
Results: The comparison between the results revealed the accuracy of HaemurEx for the above-mentioned parameters to be in the range of 85–97%.
Conclusion: HaemurEx as a screening tool has the potential to significantly impact the diagnosis and treatment of different NCDs and diseases related to women in low-resource areas. |
| format | Article |
| id | doaj-art-096ee956f93446dfbf659bbc88fdf771 |
| institution | OA Journals |
| issn | 0972-1207 2456-5164 |
| language | English |
| publishDate | 2023-12-01 |
| publisher | Jaypee Brothers Medical Publisher |
| record_format | Article |
| series | Indian Journal of Medical Biochemistry |
| spelling | doaj-art-096ee956f93446dfbf659bbc88fdf7712025-08-20T02:28:07ZengJaypee Brothers Medical PublisherIndian Journal of Medical Biochemistry0972-12072456-51642023-12-012711810.5005/jp-journals-10054-02161A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total BilirubinKusuma Kasapura Shivashankar0Swetha Nagarahalli Kempegowda1Abhijith Devaraju2Akila Prashant3Suma Maduvanahalli Nataraj4Partha Chakraborty5Amrita Mukherjee6Department of Biochemistry, JSS Medical College, JSS Academy of Higher Education and Research, Mysuru, Karnataka, IndiaDepartment of Biochemistry, JSS Medical College, JSS Academy of Higher Education and Research, Mysuru, Karnataka, IndiaDepartment of Biochemistry, JSS Medical College, JSS Academy of Higher Education and Research, Mysuru, Karnataka, IndiaDepartment of Biochemistry, JSS Medical College, JSS Academy of Higher Education and Research, Mysuru, Karnataka, IndiaDepartment of Biochemistry, JSS Medical College, JSS Academy of Higher Education and Research, Mysuru, Karnataka, IndiaDepartment of Product Development, Arogyam Medisoft Solution Pvt. Ltd, Kolkata, West Bengal, IndiaAmrita Mukherjee, Department of Product Development, Arogyam Medisoft Solution Pvt. Ltd, Kolkata, West Bengal, India, Phone: +91 9038785693Background: The rapidly increasing cases of noncommunicable diseases (NCDs) are required to be managed to maintain the sustainable development of society. HaemurEx, developed by Arogyam Medisoft Solution, is a battery-operated, lightweight, photometric clinical chemistry analyzer with the ability to transmit data to a remote health platform. It can evaluate different blood and urine biomarkers related to various NCDs and women’s health at the community level. This novel device can advance universal access to healthcare by enhancing the availability, accessibility, and affordability of testing the blood and urine biomarkers in primary health setup and thus can improve screening and monitoring of NCD conditions. The present study compares the results obtained from HaemurEx with the standard methodologies for patient care to determine its efficacy and accuracy. Materials and methods: The amount of glucose, total cholesterol, triglyceride, total bilirubin, direct bilirubin, and creatinine were estimated in 40 blood samples collected from the inpatient and outpatient facilities at JSS Medical College, Mysuru, Karnataka, India using the standard methodologies. The same samples were analyzed on the same day using HaemurEx. The results obtained from both methods were compared to validate the performance characteristics of HaemurEx for its operation. Results: The comparison between the results revealed the accuracy of HaemurEx for the above-mentioned parameters to be in the range of 85–97%. Conclusion: HaemurEx as a screening tool has the potential to significantly impact the diagnosis and treatment of different NCDs and diseases related to women in low-resource areas.https://www.ijmb.in/doi/IJMB/pdf/10.5005/jp-journals-10054-0216blood analysisclinical chemistry analyzerhaemurexnoncommunicable diseaseremote healthcare |
| spellingShingle | Kusuma Kasapura Shivashankar Swetha Nagarahalli Kempegowda Abhijith Devaraju Akila Prashant Suma Maduvanahalli Nataraj Partha Chakraborty Amrita Mukherjee A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin Indian Journal of Medical Biochemistry blood analysis clinical chemistry analyzer haemurex noncommunicable disease remote healthcare |
| title | A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin |
| title_full | A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin |
| title_fullStr | A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin |
| title_full_unstemmed | A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin |
| title_short | A Comparative Analysis between HaemurEx (Clinical Chemistry Analyzer) and Standard Methodologies for Determining Its Efficacy for Estimation of Various Blood Parameters Like Glucose, Cholesterol, Triglyceride, Creatinine, Direct Bilirubin, and Total Bilirubin |
| title_sort | comparative analysis between haemurex clinical chemistry analyzer and standard methodologies for determining its efficacy for estimation of various blood parameters like glucose cholesterol triglyceride creatinine direct bilirubin and total bilirubin |
| topic | blood analysis clinical chemistry analyzer haemurex noncommunicable disease remote healthcare |
| url | https://www.ijmb.in/doi/IJMB/pdf/10.5005/jp-journals-10054-0216 |
| work_keys_str_mv | AT kusumakasapurashivashankar acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT swethanagarahallikempegowda acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT abhijithdevaraju acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT akilaprashant acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT sumamaduvanahallinataraj acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT parthachakraborty acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT amritamukherjee acomparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT kusumakasapurashivashankar comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT swethanagarahallikempegowda comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT abhijithdevaraju comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT akilaprashant comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT sumamaduvanahallinataraj comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT parthachakraborty comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin AT amritamukherjee comparativeanalysisbetweenhaemurexclinicalchemistryanalyzerandstandardmethodologiesfordeterminingitsefficacyforestimationofvariousbloodparameterslikeglucosecholesteroltriglyceridecreatininedirectbilirubinandtotalbilirubin |