Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study

Abstract Background Aligner attachment integrity is important for clear aligner retention and overall treatment efficacy. This study aimed to evaluate the wear volume of clear aligner attachments and the retentive force change of clear aligners over a simulated 24-week insertion/removal period, alon...

Full description

Saved in:
Bibliographic Details
Main Authors: Nuttakan Roatkanjanaporn, Janeta Chavanavesh, Chutimont Teekavanich
Format: Article
Language:English
Published: BMC 2025-04-01
Series:BMC Oral Health
Subjects:
Online Access:https://doi.org/10.1186/s12903-025-05852-3
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850265459087114240
author Nuttakan Roatkanjanaporn
Janeta Chavanavesh
Chutimont Teekavanich
author_facet Nuttakan Roatkanjanaporn
Janeta Chavanavesh
Chutimont Teekavanich
author_sort Nuttakan Roatkanjanaporn
collection DOAJ
description Abstract Background Aligner attachment integrity is important for clear aligner retention and overall treatment efficacy. This study aimed to evaluate the wear volume of clear aligner attachments and the retentive force change of clear aligners over a simulated 24-week insertion/removal period, along with their correlation. Methods Attachments made from Tetric N-Flow (flowable), Beautifil Injectable X (flowable), or Filtek™ Z350 XT (sculptable) resin composites (n = 6 each) were bonded to the first premolars of maxillary dental resin models. Each model underwent a simulated 3-cycle daily insertion and removal of 12 clear aligners, with each aligner tested for 14 days, using a universal testing machine. Attachment wear volume was quantified through 3D scanning and superimposition. Average daily retentive force of aligners was measured. Data were analyzed using mixed-design ANOVA to evaluate differences in retentive force and wear volume among composites, and Pearson’s correlation to assess the relationship between wear and retentive force change. Statistical significance was set at p < 0.05. Results Significant attachment wear was observed primarily in gingival regions, without significant differences in wear volume among the three composites. Retentive force decreased significantly from days 1 to 2 and continued to decline until day 14 (p < 0.01), without significant differences in retentive force among aligners nor composite types. No significant correlation was found between attachment wear volume and the retentive force difference between the 1st and 12th aligners. Conclusions Despite reductions in attachment volume across all three composites over the 24-week period, no significant change in mean retentive force among aligners was observed. The tested composites demonstrated comparable wear resistance during repeated aligner insertion and removal over 24-week, with stable aligner retentive force, supporting their feasibility for use in clear aligner therapy.
format Article
id doaj-art-08de03a58c3a44bb831ce5d03746f88b
institution OA Journals
issn 1472-6831
language English
publishDate 2025-04-01
publisher BMC
record_format Article
series BMC Oral Health
spelling doaj-art-08de03a58c3a44bb831ce5d03746f88b2025-08-20T01:54:25ZengBMCBMC Oral Health1472-68312025-04-012511910.1186/s12903-025-05852-3Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory studyNuttakan Roatkanjanaporn0Janeta Chavanavesh1Chutimont Teekavanich2Department of Orthodontics, Faculty of Dentistry, Chulalongkorn UniversityDepartment of Orthodontics, Faculty of Dentistry, Chulalongkorn UniversityDepartment of Orthodontics, Faculty of Dentistry, Chulalongkorn UniversityAbstract Background Aligner attachment integrity is important for clear aligner retention and overall treatment efficacy. This study aimed to evaluate the wear volume of clear aligner attachments and the retentive force change of clear aligners over a simulated 24-week insertion/removal period, along with their correlation. Methods Attachments made from Tetric N-Flow (flowable), Beautifil Injectable X (flowable), or Filtek™ Z350 XT (sculptable) resin composites (n = 6 each) were bonded to the first premolars of maxillary dental resin models. Each model underwent a simulated 3-cycle daily insertion and removal of 12 clear aligners, with each aligner tested for 14 days, using a universal testing machine. Attachment wear volume was quantified through 3D scanning and superimposition. Average daily retentive force of aligners was measured. Data were analyzed using mixed-design ANOVA to evaluate differences in retentive force and wear volume among composites, and Pearson’s correlation to assess the relationship between wear and retentive force change. Statistical significance was set at p < 0.05. Results Significant attachment wear was observed primarily in gingival regions, without significant differences in wear volume among the three composites. Retentive force decreased significantly from days 1 to 2 and continued to decline until day 14 (p < 0.01), without significant differences in retentive force among aligners nor composite types. No significant correlation was found between attachment wear volume and the retentive force difference between the 1st and 12th aligners. Conclusions Despite reductions in attachment volume across all three composites over the 24-week period, no significant change in mean retentive force among aligners was observed. The tested composites demonstrated comparable wear resistance during repeated aligner insertion and removal over 24-week, with stable aligner retentive force, supporting their feasibility for use in clear aligner therapy.https://doi.org/10.1186/s12903-025-05852-3WearAttachmentResin CompositeClear AlignersRetentive force
spellingShingle Nuttakan Roatkanjanaporn
Janeta Chavanavesh
Chutimont Teekavanich
Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study
BMC Oral Health
Wear
Attachment
Resin Composite
Clear Aligners
Retentive force
title Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study
title_full Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study
title_fullStr Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study
title_full_unstemmed Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study
title_short Wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners: a laboratory study
title_sort wear volumes of flowable and sculptable resin composite attachments and their correlation with retentive force of clear aligners a laboratory study
topic Wear
Attachment
Resin Composite
Clear Aligners
Retentive force
url https://doi.org/10.1186/s12903-025-05852-3
work_keys_str_mv AT nuttakanroatkanjanaporn wearvolumesofflowableandsculptableresincompositeattachmentsandtheircorrelationwithretentiveforceofclearalignersalaboratorystudy
AT janetachavanavesh wearvolumesofflowableandsculptableresincompositeattachmentsandtheircorrelationwithretentiveforceofclearalignersalaboratorystudy
AT chutimontteekavanich wearvolumesofflowableandsculptableresincompositeattachmentsandtheircorrelationwithretentiveforceofclearalignersalaboratorystudy