Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation

Aiming at the problem of abnormal operation of three-phase voltage-type pulse width modulation (PWM) rectifier caused by factors such as voltage transformation and external disturbances, a control strategy is proposed that integrates active disturbance rejection control (ADRC) with equivalent input...

Full description

Saved in:
Bibliographic Details
Main Author: HUANG Zixin, YU Chengsong, WANG Wei, LIN Mengying, XU Da
Format: Article
Language:zho
Published: Editorial Office of Journal of Shanghai Jiao Tong University 2025-08-01
Series:Shanghai Jiaotong Daxue xuebao
Subjects:
Online Access:https://xuebao.sjtu.edu.cn/article/2025/1006-2467/1006-2467-59-8-1203.shtml
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849222015580372992
author HUANG Zixin, YU Chengsong, WANG Wei, LIN Mengying, XU Da
author_facet HUANG Zixin, YU Chengsong, WANG Wei, LIN Mengying, XU Da
author_sort HUANG Zixin, YU Chengsong, WANG Wei, LIN Mengying, XU Da
collection DOAJ
description Aiming at the problem of abnormal operation of three-phase voltage-type pulse width modulation (PWM) rectifier caused by factors such as voltage transformation and external disturbances, a control strategy is proposed that integrates active disturbance rejection control (ADRC) with equivalent input disturbance (EID) error estimation and a new terminal fuzzy sliding mode current control. By analyzing the underactuated characteristics of the three-phase voltage-type PWM rectifier system, a novel dual-closed-loop controller is constructed. The inner current loop adopts a terminal fuzzy sliding mode control strategy based on EID error estimation, while the outer voltage loop employs an ADRC strategy based on EID error estimation. To enhance controller accuracy and optimize control performance, error estimation is applied to mitigate current chattering and negative sequence current issues inherent in sliding mode control. Furthermore, harmonic components in the voltage loop are effectively suppressed, improving the voltage response speed and ensuring the stable operation of the three-phase voltage-type PWM rectifier under disturbance conditions. Finally, the proposed control strategy is validated through simulation experiments, demonstrating its effectiveness and superiority.
format Article
id doaj-art-087667ca955d472fb5013e374c856d13
institution Kabale University
issn 1006-2467
language zho
publishDate 2025-08-01
publisher Editorial Office of Journal of Shanghai Jiao Tong University
record_format Article
series Shanghai Jiaotong Daxue xuebao
spelling doaj-art-087667ca955d472fb5013e374c856d132025-08-26T09:29:34ZzhoEditorial Office of Journal of Shanghai Jiao Tong UniversityShanghai Jiaotong Daxue xuebao1006-24672025-08-015981203121510.16183/j.cnki.jsjtu.2023.508Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error EstimationHUANG Zixin, YU Chengsong, WANG Wei, LIN Mengying, XU Da0 1. School of Electrical and Information Engineering, Wuhan Institute of Technology, Wuhan 430205, China; 2. Hubei Key Laboratory of Digital Textile Equipment, Wuhan Textile University, Wuhan 430200, China; 3. School of Automation, China University of Geosciences, Wuhan 430074, ChinaAiming at the problem of abnormal operation of three-phase voltage-type pulse width modulation (PWM) rectifier caused by factors such as voltage transformation and external disturbances, a control strategy is proposed that integrates active disturbance rejection control (ADRC) with equivalent input disturbance (EID) error estimation and a new terminal fuzzy sliding mode current control. By analyzing the underactuated characteristics of the three-phase voltage-type PWM rectifier system, a novel dual-closed-loop controller is constructed. The inner current loop adopts a terminal fuzzy sliding mode control strategy based on EID error estimation, while the outer voltage loop employs an ADRC strategy based on EID error estimation. To enhance controller accuracy and optimize control performance, error estimation is applied to mitigate current chattering and negative sequence current issues inherent in sliding mode control. Furthermore, harmonic components in the voltage loop are effectively suppressed, improving the voltage response speed and ensuring the stable operation of the three-phase voltage-type PWM rectifier under disturbance conditions. Finally, the proposed control strategy is validated through simulation experiments, demonstrating its effectiveness and superiority.https://xuebao.sjtu.edu.cn/article/2025/1006-2467/1006-2467-59-8-1203.shtmlthree-phase voltage-type pulse width modulation (pwm) rectifierunderactuatedequivalent input disturbance (eid)terminal sliding controlactive disturbance rejection control (adrc)fuzzy controldual-loop control
spellingShingle HUANG Zixin, YU Chengsong, WANG Wei, LIN Mengying, XU Da
Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation
Shanghai Jiaotong Daxue xuebao
three-phase voltage-type pulse width modulation (pwm) rectifier
underactuated
equivalent input disturbance (eid)
terminal sliding control
active disturbance rejection control (adrc)
fuzzy control
dual-loop control
title Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation
title_full Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation
title_fullStr Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation
title_full_unstemmed Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation
title_short Active Disturbance Rejection Control for Underactuated PWM Rectifier Based on Equivalent Input Disturbance Error Estimation
title_sort active disturbance rejection control for underactuated pwm rectifier based on equivalent input disturbance error estimation
topic three-phase voltage-type pulse width modulation (pwm) rectifier
underactuated
equivalent input disturbance (eid)
terminal sliding control
active disturbance rejection control (adrc)
fuzzy control
dual-loop control
url https://xuebao.sjtu.edu.cn/article/2025/1006-2467/1006-2467-59-8-1203.shtml
work_keys_str_mv AT huangzixinyuchengsongwangweilinmengyingxuda activedisturbancerejectioncontrolforunderactuatedpwmrectifierbasedonequivalentinputdisturbanceerrorestimation