Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material

The grounding construction of overhead transmission line towers is restricted by the conditions of compensation for cultivated land requisition, compensation for young crops, road building blockage, and widening of line corridors.It is of practical significance to improve the dispersive capacity of...

Full description

Saved in:
Bibliographic Details
Main Author: XIE Hong-ping, HUANG Tao, FANG Xiao, AN Yun-zhu, DU Chang-qing, CHEN Yong
Format: Article
Language:zho
Published: Editorial Department of Materials Protection 2021-06-01
Series:Cailiao Baohu
Subjects:
Online Access:http://www.mat-pro.com/fileup/1001-1560/PDF/20210627.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849429081055035392
author XIE Hong-ping, HUANG Tao, FANG Xiao, AN Yun-zhu, DU Chang-qing, CHEN Yong
author_facet XIE Hong-ping, HUANG Tao, FANG Xiao, AN Yun-zhu, DU Chang-qing, CHEN Yong
author_sort XIE Hong-ping, HUANG Tao, FANG Xiao, AN Yun-zhu, DU Chang-qing, CHEN Yong
collection DOAJ
description The grounding construction of overhead transmission line towers is restricted by the conditions of compensation for cultivated land requisition, compensation for young crops, road building blockage, and widening of line corridors.It is of practical significance to improve the dispersive capacity of natural grounding of the tower foundation to reduce the grounding resistance and save construction cost.In this paper, the compact grounding strategy of tower foundation based on flexible graphite anticorrosive material was proposed.The finite element software COMSOL Multiphysics was used to establish the dispersion calculation model of the tower foundation.The grounding characteristics and influencing factors of the single tower foundation, double tower foundation and the whole four tower foundation external application method were simulated.The influence of the position of the drainage line on the characteristics of the external electrode shunt was analyzed.The calculation results showed that for the single-base concrete pile foundation, the position of the drainage line had little effect on the grounding resistance and the characteristics of the tower foundation.When the tower adopted the double foundation pit and large excavation single foundation pit, both of the external application of pile by pile and integral external application played a grounding resistance reduction effect.Considering the difficulty of construction, the amount of materials and the universality of external application, pile by pile separate external application was selected for practical tower construction.
format Article
id doaj-art-083962cd1b6142e4a3f2fd65e554da14
institution Kabale University
issn 1001-1560
language zho
publishDate 2021-06-01
publisher Editorial Department of Materials Protection
record_format Article
series Cailiao Baohu
spelling doaj-art-083962cd1b6142e4a3f2fd65e554da142025-08-20T03:28:29ZzhoEditorial Department of Materials ProtectionCailiao Baohu1001-15602021-06-0154615315810.16577/j.cnki.42-1215/tb.2021.06.028Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive MaterialXIE Hong-ping, HUANG Tao, FANG Xiao, AN Yun-zhu, DU Chang-qing, CHEN Yong0(1.State Grid Jiangsu Power Engineering Consulting Limited Company, Nanjing 210000, China;2.Electrical and Electronic Engineering College, Shandong University of Technology, Zibo 255000, China)The grounding construction of overhead transmission line towers is restricted by the conditions of compensation for cultivated land requisition, compensation for young crops, road building blockage, and widening of line corridors.It is of practical significance to improve the dispersive capacity of natural grounding of the tower foundation to reduce the grounding resistance and save construction cost.In this paper, the compact grounding strategy of tower foundation based on flexible graphite anticorrosive material was proposed.The finite element software COMSOL Multiphysics was used to establish the dispersion calculation model of the tower foundation.The grounding characteristics and influencing factors of the single tower foundation, double tower foundation and the whole four tower foundation external application method were simulated.The influence of the position of the drainage line on the characteristics of the external electrode shunt was analyzed.The calculation results showed that for the single-base concrete pile foundation, the position of the drainage line had little effect on the grounding resistance and the characteristics of the tower foundation.When the tower adopted the double foundation pit and large excavation single foundation pit, both of the external application of pile by pile and integral external application played a grounding resistance reduction effect.Considering the difficulty of construction, the amount of materials and the universality of external application, pile by pile separate external application was selected for practical tower construction.http://www.mat-pro.com/fileup/1001-1560/PDF/20210627.pdfoverhead transmission line; tower foundation; flexible graphite anticorrosive material; external applying on tower foundation; grounding resistance
spellingShingle XIE Hong-ping, HUANG Tao, FANG Xiao, AN Yun-zhu, DU Chang-qing, CHEN Yong
Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material
Cailiao Baohu
overhead transmission line; tower foundation; flexible graphite anticorrosive material; external applying on tower foundation; grounding resistance
title Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material
title_full Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material
title_fullStr Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material
title_full_unstemmed Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material
title_short Research on Compact Grounding of Tower Foundation Based on Flexible Graphite Anticorrosive Material
title_sort research on compact grounding of tower foundation based on flexible graphite anticorrosive material
topic overhead transmission line; tower foundation; flexible graphite anticorrosive material; external applying on tower foundation; grounding resistance
url http://www.mat-pro.com/fileup/1001-1560/PDF/20210627.pdf
work_keys_str_mv AT xiehongpinghuangtaofangxiaoanyunzhuduchangqingchenyong researchoncompactgroundingoftowerfoundationbasedonflexiblegraphiteanticorrosivematerial