DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY

We introduce a system of Diagnostic Reference Levels (DRLs) for patients medical exposure for national health care practice implementation. DRLs are an effective way of the patient radiation protection through the optimization of the medical exposure. The paper discusses and compares different metho...

Full description

Saved in:
Bibliographic Details
Main Authors: A. V. Vodovatov, S. A. Kalnitsky, M. I. Balonov, I. G. Kamyshanskaja
Format: Article
Language:English
Published: Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev 2015-08-01
Series:Радиационная гигиена
Subjects:
Online Access:https://www.radhyg.ru/jour/article/view/93
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849335960396890112
author A. V. Vodovatov
S. A. Kalnitsky
M. I. Balonov
I. G. Kamyshanskaja
author_facet A. V. Vodovatov
S. A. Kalnitsky
M. I. Balonov
I. G. Kamyshanskaja
author_sort A. V. Vodovatov
collection DOAJ
description We introduce a system of Diagnostic Reference Levels (DRLs) for patients medical exposure for national health care practice implementation. DRLs are an effective way of the patient radiation protection through the optimization of the medical exposure. The paper discusses and compares different methods of determining the DRLs based on measured and/or calculated quantities of patient’s dose: dose area product (DAP), entrance surface dose (ESD) and an effective dose. Distributions of different dose quantities in different Saint-Petersburg clinics are shown on the example of chest PA examinations. The results are compared with the data from other sources. Regional DRLs for Saint-Petersburg are proposed.
format Article
id doaj-art-07a867f9d49545cfbb2e5c5ccc9e923e
institution Kabale University
issn 1998-426X
language English
publishDate 2015-08-01
publisher Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
record_format Article
series Радиационная гигиена
spelling doaj-art-07a867f9d49545cfbb2e5c5ccc9e923e2025-08-20T03:45:07ZengSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. RamzaevРадиационная гигиена1998-426X2015-08-0163293692DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGYA. V. Vodovatov0S. A. Kalnitsky1M. I. Balonov2I. G. Kamyshanskaja3Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V.RamzaevSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V.RamzaevSaint-Petersburg Research Institute of Radiation Hygiene after Professor P.V.RamzaevCity Mariinskiy hospital, Saint-PetersburgWe introduce a system of Diagnostic Reference Levels (DRLs) for patients medical exposure for national health care practice implementation. DRLs are an effective way of the patient radiation protection through the optimization of the medical exposure. The paper discusses and compares different methods of determining the DRLs based on measured and/or calculated quantities of patient’s dose: dose area product (DAP), entrance surface dose (ESD) and an effective dose. Distributions of different dose quantities in different Saint-Petersburg clinics are shown on the example of chest PA examinations. The results are compared with the data from other sources. Regional DRLs for Saint-Petersburg are proposed.https://www.radhyg.ru/jour/article/view/93x-ray examinationsradiation protectionoptimizationdiagnostic reference levelentrance dosedose area producteffective dosepatient
spellingShingle A. V. Vodovatov
S. A. Kalnitsky
M. I. Balonov
I. G. Kamyshanskaja
DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY
Радиационная гигиена
x-ray examinations
radiation protection
optimization
diagnostic reference level
entrance dose
dose area product
effective dose
patient
title DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY
title_full DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY
title_fullStr DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY
title_full_unstemmed DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY
title_short DEVELOPMENT OF DIAGNOSTIC REFERENCE LEVELS (DRL) OF PATIENTS X-RAY EXPOSURE IN DIAGNOSTIC RADIOLOGY
title_sort development of diagnostic reference levels drl of patients x ray exposure in diagnostic radiology
topic x-ray examinations
radiation protection
optimization
diagnostic reference level
entrance dose
dose area product
effective dose
patient
url https://www.radhyg.ru/jour/article/view/93
work_keys_str_mv AT avvodovatov developmentofdiagnosticreferencelevelsdrlofpatientsxrayexposureindiagnosticradiology
AT sakalnitsky developmentofdiagnosticreferencelevelsdrlofpatientsxrayexposureindiagnosticradiology
AT mibalonov developmentofdiagnosticreferencelevelsdrlofpatientsxrayexposureindiagnosticradiology
AT igkamyshanskaja developmentofdiagnosticreferencelevelsdrlofpatientsxrayexposureindiagnosticradiology