Experimental verification of subthreshold laser therapy using conventional pattern scan laser.

<h4>Purpose</h4>Leading-edge therapeutic laser technologies are not available at every medical facility; therefore, alternative approaches incorporating novel advances in digital and laser technology into more readily available conventional methods have generated significant research int...

Full description

Saved in:
Bibliographic Details
Main Authors: Tomoyasu Shiraya, Satoshi Kato, Fumiyuki Araki, Takashi Ueta, Hitoshi Abe, Nobuharu Asai
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2017-01-01
Series:PLoS ONE
Online Access:https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0184392&type=printable
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850230704356458496
author Tomoyasu Shiraya
Satoshi Kato
Fumiyuki Araki
Takashi Ueta
Hitoshi Abe
Nobuharu Asai
author_facet Tomoyasu Shiraya
Satoshi Kato
Fumiyuki Araki
Takashi Ueta
Hitoshi Abe
Nobuharu Asai
author_sort Tomoyasu Shiraya
collection DOAJ
description <h4>Purpose</h4>Leading-edge therapeutic laser technologies are not available at every medical facility; therefore, alternative approaches incorporating novel advances in digital and laser technology into more readily available conventional methods have generated significant research interest. Using a rabbit model, this study investigated whether the algorithm used in the Endpoint Management (EM) software system of the latest devices could enable subthreshold laser treatment in conventional retinal tissue laser therapy systems.<h4>Materials and methods</h4>Two types of devices were used, the PASCAL Streamline 577 and the MC 500-Vixi™, and the laser method was classified into three categories: EM; single-shot using PASCAL with arbitrary energy settings (PSS-SDM); and MC500-VixiTM (VX-SDM), which were performed in eight eyes from four Dutch-Belted rabbits. In EM, 100 mW (100%) was set as a landmark, and the laser energy parameters were gradually decreased to 80%, 60%, 50%, 40%, 30%, 20%, and 10%, using a 2 × 3 square pattern. In PSS-SDM and VX-SDM, as control, the laser energy was gradually decreased to 100, 80, 60, 50, 40, 30, 20, and 10 mW. The laser settings were fixed at 200 μm, 20 ms, and a wavelength of 577 μm. To identify and compare the extent of tissue damage at each spot size, optical coherence tomography (OCT) and histological findings were used to construct a three-dimensional histopathology image using a confocal laser scanning fluorescence microscope.<h4>Results</h4>The spot size at 50% setting on EM was 7183 μm2; PSS-SDM required 50 mW (5503 μm2) to 60 mW (10279 μm2) and VX-SDM required 50 mW (7423 μm2) to create the approximate spot size. Furthermore, at 50 mW of PSS-SDM and VX-SDM, the extent of tissue damage in all three methods was generally in accord with the outer nuclear layer by OCT and inner nuclear layer by histopathological imaging.<h4>Conclusion</h4>These findings suggest that it may be possible to perform subthreshold laser therapy using approximations from the EM algorithm.
format Article
id doaj-art-07671d9d991745528456615acbf4c521
institution OA Journals
issn 1932-6203
language English
publishDate 2017-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj-art-07671d9d991745528456615acbf4c5212025-08-20T02:03:47ZengPublic Library of Science (PLoS)PLoS ONE1932-62032017-01-01129e018439210.1371/journal.pone.0184392Experimental verification of subthreshold laser therapy using conventional pattern scan laser.Tomoyasu ShirayaSatoshi KatoFumiyuki ArakiTakashi UetaHitoshi AbeNobuharu Asai<h4>Purpose</h4>Leading-edge therapeutic laser technologies are not available at every medical facility; therefore, alternative approaches incorporating novel advances in digital and laser technology into more readily available conventional methods have generated significant research interest. Using a rabbit model, this study investigated whether the algorithm used in the Endpoint Management (EM) software system of the latest devices could enable subthreshold laser treatment in conventional retinal tissue laser therapy systems.<h4>Materials and methods</h4>Two types of devices were used, the PASCAL Streamline 577 and the MC 500-Vixi™, and the laser method was classified into three categories: EM; single-shot using PASCAL with arbitrary energy settings (PSS-SDM); and MC500-VixiTM (VX-SDM), which were performed in eight eyes from four Dutch-Belted rabbits. In EM, 100 mW (100%) was set as a landmark, and the laser energy parameters were gradually decreased to 80%, 60%, 50%, 40%, 30%, 20%, and 10%, using a 2 × 3 square pattern. In PSS-SDM and VX-SDM, as control, the laser energy was gradually decreased to 100, 80, 60, 50, 40, 30, 20, and 10 mW. The laser settings were fixed at 200 μm, 20 ms, and a wavelength of 577 μm. To identify and compare the extent of tissue damage at each spot size, optical coherence tomography (OCT) and histological findings were used to construct a three-dimensional histopathology image using a confocal laser scanning fluorescence microscope.<h4>Results</h4>The spot size at 50% setting on EM was 7183 μm2; PSS-SDM required 50 mW (5503 μm2) to 60 mW (10279 μm2) and VX-SDM required 50 mW (7423 μm2) to create the approximate spot size. Furthermore, at 50 mW of PSS-SDM and VX-SDM, the extent of tissue damage in all three methods was generally in accord with the outer nuclear layer by OCT and inner nuclear layer by histopathological imaging.<h4>Conclusion</h4>These findings suggest that it may be possible to perform subthreshold laser therapy using approximations from the EM algorithm.https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0184392&type=printable
spellingShingle Tomoyasu Shiraya
Satoshi Kato
Fumiyuki Araki
Takashi Ueta
Hitoshi Abe
Nobuharu Asai
Experimental verification of subthreshold laser therapy using conventional pattern scan laser.
PLoS ONE
title Experimental verification of subthreshold laser therapy using conventional pattern scan laser.
title_full Experimental verification of subthreshold laser therapy using conventional pattern scan laser.
title_fullStr Experimental verification of subthreshold laser therapy using conventional pattern scan laser.
title_full_unstemmed Experimental verification of subthreshold laser therapy using conventional pattern scan laser.
title_short Experimental verification of subthreshold laser therapy using conventional pattern scan laser.
title_sort experimental verification of subthreshold laser therapy using conventional pattern scan laser
url https://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0184392&type=printable
work_keys_str_mv AT tomoyasushiraya experimentalverificationofsubthresholdlasertherapyusingconventionalpatternscanlaser
AT satoshikato experimentalverificationofsubthresholdlasertherapyusingconventionalpatternscanlaser
AT fumiyukiaraki experimentalverificationofsubthresholdlasertherapyusingconventionalpatternscanlaser
AT takashiueta experimentalverificationofsubthresholdlasertherapyusingconventionalpatternscanlaser
AT hitoshiabe experimentalverificationofsubthresholdlasertherapyusingconventionalpatternscanlaser
AT nobuharuasai experimentalverificationofsubthresholdlasertherapyusingconventionalpatternscanlaser