Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand

Abstract In the present investigation an attempt is made to study the axial and oblique pullout capacity of monopile and belled pile embedded in geogrid reinforced sand beds by conducting tests on model piles. A model tank of size 1.2mX0.75mX1.5 m is used to study the behaviour of an aluminium model...

Full description

Saved in:
Bibliographic Details
Main Authors: K. V. S. B. Raju, V. Lakshmi
Format: Article
Language:English
Published: SpringerOpen 2025-04-01
Series:International Journal of Geo-Engineering
Subjects:
Online Access:https://doi.org/10.1186/s40703-025-00239-3
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849737791467945984
author K. V. S. B. Raju
V. Lakshmi
author_facet K. V. S. B. Raju
V. Lakshmi
author_sort K. V. S. B. Raju
collection DOAJ
description Abstract In the present investigation an attempt is made to study the axial and oblique pullout capacity of monopile and belled pile embedded in geogrid reinforced sand beds by conducting tests on model piles. A model tank of size 1.2mX0.75mX1.5 m is used to study the behaviour of an aluminium model pile under axial and oblique pull-out loads in geogrid reinforced sand bed of relative density 30%. A comparative study was made between monopile and belled piles by varying parameters such as embedment ratios (L/Ds) of 5, 7.5, and 10 respectively and diameter ratios (Db/Ds) of 1.5 & 2 with bell angles of 30°, 45°, and 60° under axial and oblique inclination angle of 30˚& 45˚.The use of the optimum size of the geogrid reinforcement placed at the bottom of the short pile and at a spacing of 4.5Ds from top in case of intermediate and long pile significantly enhanced the pullout and oblique pullout capacities of both monopile and belled piles. In the case of a monopile, the pull-out capacity increases with an increase in the load inclination angle from 0˚ to 45°, whereas in the case of the belled pile, the pullout capacity decreased with an increase in the load inclination angle. A non-dimensional parameter called the Uplift Improvement Ratio was evaluated, and the results revealed that the efficiency of the geogrid reinforcement was independent of the load inclination, bell angle, Db/Ds ratio, and L/Ds ratio when the optimum size of the geogrid was placed at optimum position of the belled pile foundation. It was also found that the obtained breakout factor increases with an increase in the L/Ds ratio and load inclination angle but the influence of the bell angle on the breakout factor was found to be marginal.The obtained values of the breakout factor were compared with the existing limit equilibrium theory, and it was found that the results of the breakout factor were in good agreement with the Meyerhof and Adam theory for both unreinforced and geogrid-reinforced sand beds.
format Article
id doaj-art-070327ef8a0d4b8894950365644778fb
institution DOAJ
issn 2198-2783
language English
publishDate 2025-04-01
publisher SpringerOpen
record_format Article
series International Journal of Geo-Engineering
spelling doaj-art-070327ef8a0d4b8894950365644778fb2025-08-20T03:06:48ZengSpringerOpenInternational Journal of Geo-Engineering2198-27832025-04-0116113710.1186/s40703-025-00239-3Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sandK. V. S. B. Raju0V. Lakshmi1Department of CivilEngineering, UVCEDepartment of CivilEngineering, UVCEAbstract In the present investigation an attempt is made to study the axial and oblique pullout capacity of monopile and belled pile embedded in geogrid reinforced sand beds by conducting tests on model piles. A model tank of size 1.2mX0.75mX1.5 m is used to study the behaviour of an aluminium model pile under axial and oblique pull-out loads in geogrid reinforced sand bed of relative density 30%. A comparative study was made between monopile and belled piles by varying parameters such as embedment ratios (L/Ds) of 5, 7.5, and 10 respectively and diameter ratios (Db/Ds) of 1.5 & 2 with bell angles of 30°, 45°, and 60° under axial and oblique inclination angle of 30˚& 45˚.The use of the optimum size of the geogrid reinforcement placed at the bottom of the short pile and at a spacing of 4.5Ds from top in case of intermediate and long pile significantly enhanced the pullout and oblique pullout capacities of both monopile and belled piles. In the case of a monopile, the pull-out capacity increases with an increase in the load inclination angle from 0˚ to 45°, whereas in the case of the belled pile, the pullout capacity decreased with an increase in the load inclination angle. A non-dimensional parameter called the Uplift Improvement Ratio was evaluated, and the results revealed that the efficiency of the geogrid reinforcement was independent of the load inclination, bell angle, Db/Ds ratio, and L/Ds ratio when the optimum size of the geogrid was placed at optimum position of the belled pile foundation. It was also found that the obtained breakout factor increases with an increase in the L/Ds ratio and load inclination angle but the influence of the bell angle on the breakout factor was found to be marginal.The obtained values of the breakout factor were compared with the existing limit equilibrium theory, and it was found that the results of the breakout factor were in good agreement with the Meyerhof and Adam theory for both unreinforced and geogrid-reinforced sand beds.https://doi.org/10.1186/s40703-025-00239-3Axialand oblique pull-out CapacityBelled PileLoad Inclination angleBell diameter ratio (Db/Ds)Embedment ratio (L/Ds)Spacing ratio (S/Ds)
spellingShingle K. V. S. B. Raju
V. Lakshmi
Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
International Journal of Geo-Engineering
Axialand oblique pull-out Capacity
Belled Pile
Load Inclination angle
Bell diameter ratio (Db/Ds)
Embedment ratio (L/Ds)
Spacing ratio (S/Ds)
title Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
title_full Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
title_fullStr Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
title_full_unstemmed Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
title_short Pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
title_sort pullout and oblique pullout resistance of enlarged base piles in geogrid reinforced sand
topic Axialand oblique pull-out Capacity
Belled Pile
Load Inclination angle
Bell diameter ratio (Db/Ds)
Embedment ratio (L/Ds)
Spacing ratio (S/Ds)
url https://doi.org/10.1186/s40703-025-00239-3
work_keys_str_mv AT kvsbraju pulloutandobliquepulloutresistanceofenlargedbasepilesingeogridreinforcedsand
AT vlakshmi pulloutandobliquepulloutresistanceofenlargedbasepilesingeogridreinforcedsand