Effects of Flow Regime and Heat Source Simplifications on Simulation Results for Water-Cooling Plate of IGBT
By comparing laminar and turbulent models, the flow regime of water-cooling plate with straight channels was researched; the results showed that the average velocities were different in channels, and it was improper to set the flow regime of all channels with laminar or turbulent. The highest differ...
Saved in:
| Main Authors: | 丁杰, 李江红, 陈燕平, 张陈林 |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Department of Electric Drive for Locomotives
2011-01-01
|
| Series: | 机车电传动 |
| Subjects: | |
| Online Access: | http://edl.csrzic.com/thesisDetails#10.13890/j.issn.1000-128x.2011.05.010 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Effects of Mesh Size on Simulation Results of Water-Cooling Radiator for IGBT Module
by: 丁杰, et al.
Published: (2012-01-01) -
Design of High Voltage IGBT Converter Module for High Power Test Bed
by: LIU Feng, et al.
Published: (2017-01-01) -
The Simplification of IGBT Traction Inverter for Metro Vehicle
by: 翁星方, et al.
Published: (2011-01-01) -
Temperature-rise Test and Thermal Simulation for IGBT Water-cooled Radiator
of Motor Controller
by: DING Jie, et al.
Published: (2015-01-01) -
TGA16 Type IGBT Converter for High-speed Test EMUs
by: WENG Xing-fang, et al.
Published: (2014-01-01)