Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS

Ivermectin, a veterinary drug, is commonly used endectocide for animal husbandry. The drug is available in the form of subcutaneous or topical formulations. Its application may cause accumulation of its residues into the animal tissues, which ultimately find their way into the food products, such as...

Full description

Saved in:
Bibliographic Details
Main Authors: Meenakshi Dahiya, Shanta Sen, Kiran Lamba, Manjeet Aggarwal, R. K. Khandal
Format: Article
Language:English
Published: Wiley 2010-01-01
Series:E-Journal of Chemistry
Online Access:http://dx.doi.org/10.1155/2010/249542
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849308490798989312
author Meenakshi Dahiya
Shanta Sen
Kiran Lamba
Manjeet Aggarwal
R. K. Khandal
author_facet Meenakshi Dahiya
Shanta Sen
Kiran Lamba
Manjeet Aggarwal
R. K. Khandal
author_sort Meenakshi Dahiya
collection DOAJ
description Ivermectin, a veterinary drug, is commonly used endectocide for animal husbandry. The drug is available in the form of subcutaneous or topical formulations. Its application may cause accumulation of its residues into the animal tissues, which ultimately find their way into the food products, such as milk and meat products. In order to determine the residues of ivermectin in milk, a comparatively simple, sensitive and rapid method was developed and validated using LC-MS/MS. The MRM transitions corresponding to m/z 892.71>569.6, 892.71>551.5 and 892.71>307.3 were used for the purpose of quantification and evaluation of other parameters of the method. The limit of detection of the method was found to be 0.1 μg/kg and the limit of quantitation was calculated as 0.2 μg/kg. The method was found to be linear in the range of 1.0 ng/mL to 100.0 ng/mL with correlation coefficient of 0.9992 for pure calibration curve and 0.9990 for the matrix- matched calibration curve. The recoveries of ivermectin from the spiked samples of raw milk were found between 85 to 105%.
format Article
id doaj-art-05336654665e4f6d858015b32f0fe9d2
institution Kabale University
issn 0973-4945
2090-9810
language English
publishDate 2010-01-01
publisher Wiley
record_format Article
series E-Journal of Chemistry
spelling doaj-art-05336654665e4f6d858015b32f0fe9d22025-08-20T03:54:25ZengWileyE-Journal of Chemistry0973-49452090-98102010-01-017S1S267S27710.1155/2010/249542Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MSMeenakshi Dahiya0Shanta Sen1Kiran Lamba2Manjeet Aggarwal3R. K. Khandal4Shriram Institute for Industrial Research University Road, Delhi-110007, IndiaShriram Institute for Industrial Research University Road, Delhi-110007, IndiaShriram Institute for Industrial Research University Road, Delhi-110007, IndiaShriram Institute for Industrial Research University Road, Delhi-110007, IndiaShriram Institute for Industrial Research University Road, Delhi-110007, IndiaIvermectin, a veterinary drug, is commonly used endectocide for animal husbandry. The drug is available in the form of subcutaneous or topical formulations. Its application may cause accumulation of its residues into the animal tissues, which ultimately find their way into the food products, such as milk and meat products. In order to determine the residues of ivermectin in milk, a comparatively simple, sensitive and rapid method was developed and validated using LC-MS/MS. The MRM transitions corresponding to m/z 892.71>569.6, 892.71>551.5 and 892.71>307.3 were used for the purpose of quantification and evaluation of other parameters of the method. The limit of detection of the method was found to be 0.1 μg/kg and the limit of quantitation was calculated as 0.2 μg/kg. The method was found to be linear in the range of 1.0 ng/mL to 100.0 ng/mL with correlation coefficient of 0.9992 for pure calibration curve and 0.9990 for the matrix- matched calibration curve. The recoveries of ivermectin from the spiked samples of raw milk were found between 85 to 105%.http://dx.doi.org/10.1155/2010/249542
spellingShingle Meenakshi Dahiya
Shanta Sen
Kiran Lamba
Manjeet Aggarwal
R. K. Khandal
Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS
E-Journal of Chemistry
title Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS
title_full Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS
title_fullStr Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS
title_full_unstemmed Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS
title_short Quantitative Determination of Ivermectin in Raw Milk Using Positive ESI LC-MS/MS
title_sort quantitative determination of ivermectin in raw milk using positive esi lc ms ms
url http://dx.doi.org/10.1155/2010/249542
work_keys_str_mv AT meenakshidahiya quantitativedeterminationofivermectininrawmilkusingpositiveesilcmsms
AT shantasen quantitativedeterminationofivermectininrawmilkusingpositiveesilcmsms
AT kiranlamba quantitativedeterminationofivermectininrawmilkusingpositiveesilcmsms
AT manjeetaggarwal quantitativedeterminationofivermectininrawmilkusingpositiveesilcmsms
AT rkkhandal quantitativedeterminationofivermectininrawmilkusingpositiveesilcmsms