Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery

The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries...

Full description

Saved in:
Bibliographic Details
Main Authors: Sang Beom Han, Yu-Chi Liu, Karim Mohamed-Noriega, Jodhbir S. Mehta
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2022/1568406
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832545210368786432
author Sang Beom Han
Yu-Chi Liu
Karim Mohamed-Noriega
Jodhbir S. Mehta
author_facet Sang Beom Han
Yu-Chi Liu
Karim Mohamed-Noriega
Jodhbir S. Mehta
author_sort Sang Beom Han
collection DOAJ
description The use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries, i.e., cornea, cataract, and refractive surgery. iOCT has enabled real-time precise visualization of anterior segment tissues as well as interactions between surgical instruments and ocular tissue; thus, the device can facilitate surgical procedures and provide valuable information for decision-making during anterior segment surgeries. In this review, the authors will introduce studies regarding the development of iOCT technology and its application in various anterior segment surgeries. Multiple studies have shown the efficacy of the iOCT for intraoperative assistance and guidance, suggesting the potential of the device for optimizing the surgical outcomes after cornea, cataract, and refractive surgery.
format Article
id doaj-art-04590c8e06e1406698fe20936546f1a9
institution Kabale University
issn 2090-0058
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-04590c8e06e1406698fe20936546f1a92025-02-03T07:26:19ZengWileyJournal of Ophthalmology2090-00582022-01-01202210.1155/2022/1568406Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment SurgerySang Beom Han0Yu-Chi Liu1Karim Mohamed-Noriega2Jodhbir S. Mehta3Department of OphthalmologySingapore National Eye CentreDepartment of OphthalmologySingapore National Eye CentreThe use of optical coherence tomography (OCT) technology in anterior segment diseases allows for precise assessment of the changes following anterior segment surgery. Advances in microscope-integrated OCT systems have allowed the utilization of intraoperative OCT (iOCT) in anterior segment surgeries, i.e., cornea, cataract, and refractive surgery. iOCT has enabled real-time precise visualization of anterior segment tissues as well as interactions between surgical instruments and ocular tissue; thus, the device can facilitate surgical procedures and provide valuable information for decision-making during anterior segment surgeries. In this review, the authors will introduce studies regarding the development of iOCT technology and its application in various anterior segment surgeries. Multiple studies have shown the efficacy of the iOCT for intraoperative assistance and guidance, suggesting the potential of the device for optimizing the surgical outcomes after cornea, cataract, and refractive surgery.http://dx.doi.org/10.1155/2022/1568406
spellingShingle Sang Beom Han
Yu-Chi Liu
Karim Mohamed-Noriega
Jodhbir S. Mehta
Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
Journal of Ophthalmology
title Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_full Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_fullStr Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_full_unstemmed Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_short Application of Intraoperative Optical Coherence Tomography Technology in Anterior Segment Surgery
title_sort application of intraoperative optical coherence tomography technology in anterior segment surgery
url http://dx.doi.org/10.1155/2022/1568406
work_keys_str_mv AT sangbeomhan applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery
AT yuchiliu applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery
AT karimmohamednoriega applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery
AT jodhbirsmehta applicationofintraoperativeopticalcoherencetomographytechnologyinanteriorsegmentsurgery