ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR
Exact formulas for calculation of limiting values of transmitted capacity and efficiency of lines of a variable voltage with active loading on the reception end are resulted. Critical resistance and losses of capacity are determined depending on length Air-lines of an electricity transmission of a c...
Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Academy of Sciences of Moldova
2008-04-01
|
| Series: | Problems of the Regional Energetics |
| Subjects: | |
| Online Access: | http://journal.ie.asm.md/assets/files/m71_2_65.doc |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849412811913953280 |
|---|---|
| author | Rimsky V.X. Berzan V.P. Patsiuk V.I. Karcheva N.F. Andros I.V. |
| author_facet | Rimsky V.X. Berzan V.P. Patsiuk V.I. Karcheva N.F. Andros I.V. |
| author_sort | Rimsky V.X. |
| collection | DOAJ |
| description | Exact formulas for calculation of limiting values of transmitted capacity and efficiency of lines of a variable voltage with active loading on the reception end are resulted. Critical resistance and losses of capacity are determined depending on length Air-lines of an electricity transmission of a class of a voltage 500 … 750 kV. Emergency operation in the loaded electricity transmission is investigated. |
| format | Article |
| id | doaj-art-042f82cb855240b9aa83a3f5c7e762a2 |
| institution | Kabale University |
| issn | 1857-0070 |
| language | English |
| publishDate | 2008-04-01 |
| publisher | Academy of Sciences of Moldova |
| record_format | Article |
| series | Problems of the Regional Energetics |
| spelling | doaj-art-042f82cb855240b9aa83a3f5c7e762a22025-08-20T03:34:20ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702008-04-012008-115267ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIORRimsky V.X.0Berzan V.P.1Patsiuk V.I.2Karcheva N.F.3Andros I.V.4Institute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republic of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaExact formulas for calculation of limiting values of transmitted capacity and efficiency of lines of a variable voltage with active loading on the reception end are resulted. Critical resistance and losses of capacity are determined depending on length Air-lines of an electricity transmission of a class of a voltage 500 … 750 kV. Emergency operation in the loaded electricity transmission is investigated.http://journal.ie.asm.md/assets/files/m71_2_65.doccable equationsaactive capacity |
| spellingShingle | Rimsky V.X. Berzan V.P. Patsiuk V.I. Karcheva N.F. Andros I.V. ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR Problems of the Regional Energetics cable equations a active capacity |
| title | ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR |
| title_full | ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR |
| title_fullStr | ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR |
| title_full_unstemmed | ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR |
| title_short | ACTIVE POWER LOSSES IN LONG LINES DURING COORDINATED, LIMITING AND MALFUNCTION BEHAVIOR |
| title_sort | active power losses in long lines during coordinated limiting and malfunction behavior |
| topic | cable equations a active capacity |
| url | http://journal.ie.asm.md/assets/files/m71_2_65.doc |
| work_keys_str_mv | AT rimskyvx activepowerlossesinlonglinesduringcoordinatedlimitingandmalfunctionbehavior AT berzanvp activepowerlossesinlonglinesduringcoordinatedlimitingandmalfunctionbehavior AT patsiukvi activepowerlossesinlonglinesduringcoordinatedlimitingandmalfunctionbehavior AT karchevanf activepowerlossesinlonglinesduringcoordinatedlimitingandmalfunctionbehavior AT androsiv activepowerlossesinlonglinesduringcoordinatedlimitingandmalfunctionbehavior |