High-frequency echography of the eye in macular hole diagnosis

Purpose: a comparative estimation of ultrasound examinations of the posterior eye pole of patients with a macular hole using a long-focus high-frequency (20 MHz) and a standard 10 MHz probe with optical coherence tomography (OCT).Materials and methods. 20 patients with a macular hole in at least one...

Full description

Saved in:
Bibliographic Details
Main Authors: T. N. Kiseleva, K. V. Lugovkina, A. N. Bedretdinov, P. A. Bychkov, M. V. Ryabina, M. S. Zaytsev
Format: Article
Language:Russian
Published: Real Time Ltd 2022-09-01
Series:Российский офтальмологический журнал
Subjects:
Online Access:https://roj.igb.ru/jour/article/view/1046
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849696627644694528
author T. N. Kiseleva
K. V. Lugovkina
A. N. Bedretdinov
P. A. Bychkov
M. V. Ryabina
M. S. Zaytsev
author_facet T. N. Kiseleva
K. V. Lugovkina
A. N. Bedretdinov
P. A. Bychkov
M. V. Ryabina
M. S. Zaytsev
author_sort T. N. Kiseleva
collection DOAJ
description Purpose: a comparative estimation of ultrasound examinations of the posterior eye pole of patients with a macular hole using a long-focus high-frequency (20 MHz) and a standard 10 MHz probe with optical coherence tomography (OCT).Materials and methods. 20 patients with a macular hole in at least one eye were examined using OCT of the macular area and B-mode echography with a standard 10 MHz probe and a long-focus high-frequency 20 MHz probe.Results. The complex OCT/ ultrasound examination detected a macular hole in 22 (100 %) eyes, while OCT alone confirmed the diagnosis in 20 eyes (91 %). OCT could not be performed in 2 eyes due to a dense cataract. Ultrasound examination with a 20-MHz probe detected a macular hole in 16 eyes (73 %), whilst the standard ultrasound method (10 MHz probe) could only detect it in 10 eyes (45 %).Conclusion. High-frequency ultrasound examination of the eye can be used for screening aimed at detecting a possible macular hole in cases of opacities of the optical media of the eye.
format Article
id doaj-art-030a65248ab94b5aba880e8760116ee0
institution DOAJ
issn 2072-0076
2587-5760
language Russian
publishDate 2022-09-01
publisher Real Time Ltd
record_format Article
series Российский офтальмологический журнал
spelling doaj-art-030a65248ab94b5aba880e8760116ee02025-08-20T03:19:24ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602022-09-01153343910.21516/2072-0076-2022-15-3-34-39494High-frequency echography of the eye in macular hole diagnosisT. N. Kiseleva0K. V. Lugovkina1A. N. Bedretdinov2P. A. Bychkov3M. V. Ryabina4M. S. Zaytsev5Helmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesPurpose: a comparative estimation of ultrasound examinations of the posterior eye pole of patients with a macular hole using a long-focus high-frequency (20 MHz) and a standard 10 MHz probe with optical coherence tomography (OCT).Materials and methods. 20 patients with a macular hole in at least one eye were examined using OCT of the macular area and B-mode echography with a standard 10 MHz probe and a long-focus high-frequency 20 MHz probe.Results. The complex OCT/ ultrasound examination detected a macular hole in 22 (100 %) eyes, while OCT alone confirmed the diagnosis in 20 eyes (91 %). OCT could not be performed in 2 eyes due to a dense cataract. Ultrasound examination with a 20-MHz probe detected a macular hole in 16 eyes (73 %), whilst the standard ultrasound method (10 MHz probe) could only detect it in 10 eyes (45 %).Conclusion. High-frequency ultrasound examination of the eye can be used for screening aimed at detecting a possible macular hole in cases of opacities of the optical media of the eye.https://roj.igb.ru/jour/article/view/1046macular holeoptical coherence tomographyultrasound examinationlong focal high-frequency probe
spellingShingle T. N. Kiseleva
K. V. Lugovkina
A. N. Bedretdinov
P. A. Bychkov
M. V. Ryabina
M. S. Zaytsev
High-frequency echography of the eye in macular hole diagnosis
Российский офтальмологический журнал
macular hole
optical coherence tomography
ultrasound examination
long focal high-frequency probe
title High-frequency echography of the eye in macular hole diagnosis
title_full High-frequency echography of the eye in macular hole diagnosis
title_fullStr High-frequency echography of the eye in macular hole diagnosis
title_full_unstemmed High-frequency echography of the eye in macular hole diagnosis
title_short High-frequency echography of the eye in macular hole diagnosis
title_sort high frequency echography of the eye in macular hole diagnosis
topic macular hole
optical coherence tomography
ultrasound examination
long focal high-frequency probe
url https://roj.igb.ru/jour/article/view/1046
work_keys_str_mv AT tnkiseleva highfrequencyechographyoftheeyeinmacularholediagnosis
AT kvlugovkina highfrequencyechographyoftheeyeinmacularholediagnosis
AT anbedretdinov highfrequencyechographyoftheeyeinmacularholediagnosis
AT pabychkov highfrequencyechographyoftheeyeinmacularholediagnosis
AT mvryabina highfrequencyechographyoftheeyeinmacularholediagnosis
AT mszaytsev highfrequencyechographyoftheeyeinmacularholediagnosis