High-frequency echography of the eye in macular hole diagnosis
Purpose: a comparative estimation of ultrasound examinations of the posterior eye pole of patients with a macular hole using a long-focus high-frequency (20 MHz) and a standard 10 MHz probe with optical coherence tomography (OCT).Materials and methods. 20 patients with a macular hole in at least one...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | Russian |
| Published: |
Real Time Ltd
2022-09-01
|
| Series: | Российский офтальмологический журнал |
| Subjects: | |
| Online Access: | https://roj.igb.ru/jour/article/view/1046 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849696627644694528 |
|---|---|
| author | T. N. Kiseleva K. V. Lugovkina A. N. Bedretdinov P. A. Bychkov M. V. Ryabina M. S. Zaytsev |
| author_facet | T. N. Kiseleva K. V. Lugovkina A. N. Bedretdinov P. A. Bychkov M. V. Ryabina M. S. Zaytsev |
| author_sort | T. N. Kiseleva |
| collection | DOAJ |
| description | Purpose: a comparative estimation of ultrasound examinations of the posterior eye pole of patients with a macular hole using a long-focus high-frequency (20 MHz) and a standard 10 MHz probe with optical coherence tomography (OCT).Materials and methods. 20 patients with a macular hole in at least one eye were examined using OCT of the macular area and B-mode echography with a standard 10 MHz probe and a long-focus high-frequency 20 MHz probe.Results. The complex OCT/ ultrasound examination detected a macular hole in 22 (100 %) eyes, while OCT alone confirmed the diagnosis in 20 eyes (91 %). OCT could not be performed in 2 eyes due to a dense cataract. Ultrasound examination with a 20-MHz probe detected a macular hole in 16 eyes (73 %), whilst the standard ultrasound method (10 MHz probe) could only detect it in 10 eyes (45 %).Conclusion. High-frequency ultrasound examination of the eye can be used for screening aimed at detecting a possible macular hole in cases of opacities of the optical media of the eye. |
| format | Article |
| id | doaj-art-030a65248ab94b5aba880e8760116ee0 |
| institution | DOAJ |
| issn | 2072-0076 2587-5760 |
| language | Russian |
| publishDate | 2022-09-01 |
| publisher | Real Time Ltd |
| record_format | Article |
| series | Российский офтальмологический журнал |
| spelling | doaj-art-030a65248ab94b5aba880e8760116ee02025-08-20T03:19:24ZrusReal Time LtdРоссийский офтальмологический журнал2072-00762587-57602022-09-01153343910.21516/2072-0076-2022-15-3-34-39494High-frequency echography of the eye in macular hole diagnosisT. N. Kiseleva0K. V. Lugovkina1A. N. Bedretdinov2P. A. Bychkov3M. V. Ryabina4M. S. Zaytsev5Helmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesHelmholtz National Medical Research Center of Eye DiseasesPurpose: a comparative estimation of ultrasound examinations of the posterior eye pole of patients with a macular hole using a long-focus high-frequency (20 MHz) and a standard 10 MHz probe with optical coherence tomography (OCT).Materials and methods. 20 patients with a macular hole in at least one eye were examined using OCT of the macular area and B-mode echography with a standard 10 MHz probe and a long-focus high-frequency 20 MHz probe.Results. The complex OCT/ ultrasound examination detected a macular hole in 22 (100 %) eyes, while OCT alone confirmed the diagnosis in 20 eyes (91 %). OCT could not be performed in 2 eyes due to a dense cataract. Ultrasound examination with a 20-MHz probe detected a macular hole in 16 eyes (73 %), whilst the standard ultrasound method (10 MHz probe) could only detect it in 10 eyes (45 %).Conclusion. High-frequency ultrasound examination of the eye can be used for screening aimed at detecting a possible macular hole in cases of opacities of the optical media of the eye.https://roj.igb.ru/jour/article/view/1046macular holeoptical coherence tomographyultrasound examinationlong focal high-frequency probe |
| spellingShingle | T. N. Kiseleva K. V. Lugovkina A. N. Bedretdinov P. A. Bychkov M. V. Ryabina M. S. Zaytsev High-frequency echography of the eye in macular hole diagnosis Российский офтальмологический журнал macular hole optical coherence tomography ultrasound examination long focal high-frequency probe |
| title | High-frequency echography of the eye in macular hole diagnosis |
| title_full | High-frequency echography of the eye in macular hole diagnosis |
| title_fullStr | High-frequency echography of the eye in macular hole diagnosis |
| title_full_unstemmed | High-frequency echography of the eye in macular hole diagnosis |
| title_short | High-frequency echography of the eye in macular hole diagnosis |
| title_sort | high frequency echography of the eye in macular hole diagnosis |
| topic | macular hole optical coherence tomography ultrasound examination long focal high-frequency probe |
| url | https://roj.igb.ru/jour/article/view/1046 |
| work_keys_str_mv | AT tnkiseleva highfrequencyechographyoftheeyeinmacularholediagnosis AT kvlugovkina highfrequencyechographyoftheeyeinmacularholediagnosis AT anbedretdinov highfrequencyechographyoftheeyeinmacularholediagnosis AT pabychkov highfrequencyechographyoftheeyeinmacularholediagnosis AT mvryabina highfrequencyechographyoftheeyeinmacularholediagnosis AT mszaytsev highfrequencyechographyoftheeyeinmacularholediagnosis |