Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function

The existing open heat-source tower has high moisture absorption rate in winter, which affects the safety of system. So a new-type heat-source tower structure with pre-condensation function was designed. The operation process of new-type tower was analyzed. The operation characteristic of new-type t...

Full description

Saved in:
Bibliographic Details
Main Authors: Xia Yi, Sun Libiao, Liang Caihua, Zhang Xiaosong
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2015-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.06.047
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850071713683865600
author Xia Yi
Sun Libiao
Liang Caihua
Zhang Xiaosong
author_facet Xia Yi
Sun Libiao
Liang Caihua
Zhang Xiaosong
author_sort Xia Yi
collection DOAJ
description The existing open heat-source tower has high moisture absorption rate in winter, which affects the safety of system. So a new-type heat-source tower structure with pre-condensation function was designed. The operation process of new-type tower was analyzed. The operation characteristic of new-type tower and ordinary tower were comparatively studied under different inlet solution temperature, mass flow of air and solution. The experiment results showed that the new-type tower had higher heat exchange performance and lower moisture absorption rate. Compared with ordinary tower, when inlet solution temperature rise from 1 ℃to 3 ℃, the new-type tower’s heat exchange rate increased 0.62 - 0.24 kW, and moisture absorption rate dropped 0.13 g/s in average; When air flow increased from 1.41 kg/s to 2.17 kg/s, the new-type tower’s heat exchange rate increased 0.79 - 0.84 kW, and moisture absorption rate dropped 0.1 g/s in average; When solution flow rate increased from 0.36 kg/s to 0.68 kg/s, the new-type tower’s heat exchange rate increased f 0.57 - 0.63 kW , and moisture absorption rate dropped 0.11 g/s in average.
format Article
id doaj-art-02dca0a67bae4d55bbad01dacddecea2
institution DOAJ
issn 0253-4339
language zho
publishDate 2015-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-02dca0a67bae4d55bbad01dacddecea22025-08-20T02:47:14ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392015-01-013666516021Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation FunctionXia YiSun LibiaoLiang CaihuaZhang XiaosongThe existing open heat-source tower has high moisture absorption rate in winter, which affects the safety of system. So a new-type heat-source tower structure with pre-condensation function was designed. The operation process of new-type tower was analyzed. The operation characteristic of new-type tower and ordinary tower were comparatively studied under different inlet solution temperature, mass flow of air and solution. The experiment results showed that the new-type tower had higher heat exchange performance and lower moisture absorption rate. Compared with ordinary tower, when inlet solution temperature rise from 1 ℃to 3 ℃, the new-type tower’s heat exchange rate increased 0.62 - 0.24 kW, and moisture absorption rate dropped 0.13 g/s in average; When air flow increased from 1.41 kg/s to 2.17 kg/s, the new-type tower’s heat exchange rate increased 0.79 - 0.84 kW, and moisture absorption rate dropped 0.1 g/s in average; When solution flow rate increased from 0.36 kg/s to 0.68 kg/s, the new-type tower’s heat exchange rate increased f 0.57 - 0.63 kW , and moisture absorption rate dropped 0.11 g/s in average.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.06.047heat-source towerheat and mass transferoperating conditionspre-condensation function
spellingShingle Xia Yi
Sun Libiao
Liang Caihua
Zhang Xiaosong
Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function
Zhileng xuebao
heat-source tower
heat and mass transfer
operating conditions
pre-condensation function
title Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function
title_full Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function
title_fullStr Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function
title_full_unstemmed Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function
title_short Experimental Study on the Performance Characteristic of a New-type Heat-source Tower with Pre-condensation Function
title_sort experimental study on the performance characteristic of a new type heat source tower with pre condensation function
topic heat-source tower
heat and mass transfer
operating conditions
pre-condensation function
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2015.06.047
work_keys_str_mv AT xiayi experimentalstudyontheperformancecharacteristicofanewtypeheatsourcetowerwithprecondensationfunction
AT sunlibiao experimentalstudyontheperformancecharacteristicofanewtypeheatsourcetowerwithprecondensationfunction
AT liangcaihua experimentalstudyontheperformancecharacteristicofanewtypeheatsourcetowerwithprecondensationfunction
AT zhangxiaosong experimentalstudyontheperformancecharacteristicofanewtypeheatsourcetowerwithprecondensationfunction