Mechanical Power Is Associated With Mortality in Pressure-Controlled Ventilated Patients: A Dutch, Single-Center Cohort Study

IMPORTANCE:. Mechanical power (MP) could serve as a valuable parameter in clinical practice to estimate the likelihood of adverse outcomes. However, the safety thresholds for MP in mechanical ventilation remain underexplored and contentious. OBJECTIVES:. This study aims to investigate the associatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamilla Goedegebuur, MD, Floor E. Smits, MSc, Jacob W. M. Snoep, BSc, Petra J. Rietveld, BSc, Franciska van der Velde, MD, Evert de Jonge, MD, PhD, Abraham Schoe, MD, PhD
Format: Article
Language:English
Published: Wolters Kluwer 2024-12-01
Series:Critical Care Explorations
Online Access:http://journals.lww.com/10.1097/CCE.0000000000001190
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:IMPORTANCE:. Mechanical power (MP) could serve as a valuable parameter in clinical practice to estimate the likelihood of adverse outcomes. However, the safety thresholds for MP in mechanical ventilation remain underexplored and contentious. OBJECTIVES:. This study aims to investigate the association between MP and hospital mortality across varying degrees of lung disease severity, classified by Pao2/Fio2 ratios. DESIGN, SETTING, AND PARTICIPANTS:. This is a retrospective cohort study using automatically extracted data. Patients admitted to the ICU of a tertiary referral hospital in The Netherlands between 2018 and 2024 and ventilated in pressure-controlled mode were included. MAIN OUTCOMES AND MEASURES:. Logistic regression, adjusted for age, sex, Acute Physiology and Chronic Health Evaluation-IV score, and Pao2/Fio2 ratio, was used to calculate the odds ratio (OR) for all-cause in-hospital mortality. RESULTS:. A total of 2184 patients were analyzed, with a mean age of 62.5 ± 13.8 years, of whom 1508 (70.2%) were male. The mean MP was highest in patients with the lowest Pao2/Fio2 ratios (21.5 ± 6.5 J/min) compared with those with the highest ratios (12.0 ± 3.8 J/min; p < 0.001). Adjusted analyses revealed that increased MP was associated with higher mortality (OR, 1.06; 95% CI, 1.03–1.09 per J/min increase). Similarly, MP normalized for body weight showed a stronger association with mortality (OR, 1.004; 95% CI, 1.002–1.006 per J/min/kg increase). An increase in mortality was seen when MP exceeded 16–18 J/min. CONCLUSIONS AND RELEVANCE:. Our findings demonstrate a significant association between MP and hospital mortality, even after adjusting for key confounders. Mortality increases notably when MP exceeds 16–18 J/min. Normalized MP presents an even stronger association with mortality. These results underscore the need for further research into ventilation strategies that consider MP adjustments.
ISSN:2639-8028