Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a fl...

Full description

Saved in:
Bibliographic Details
Main Author: Huda Majid Hasen
Format: Article
Language:English
Published: University of Baghdad, College of Science for Women 2023-08-01
Series:مجلة بغداد للعلوم
Subjects:
Online Access:https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/7584
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849412999181238272
author Huda Majid Hasen
author_facet Huda Majid Hasen
author_sort Huda Majid Hasen
collection DOAJ
description This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670 mm. Nusselt number, overall heat transfer coefficient, convective heat transfer coefficient (CHTC), friction factor and pressure drop were measured from the obtained experimental results and plotted in graphs against Reynold number and volumetric flow rate of water. These parameters appeared good results in the cooling process. Nusselt numbers increased linearly with DIW flow rate for both C1 and C2 reaching maximum values of 38.25 and 14.64 respectively. CHTC increased linearly with the DIW flow rate for both C1 and C2 reaching maximum values of 2934.3 and 871.7 respectively. Overall heat transfer coefficient of DIW reached maximum values of 296.36 and 251.4 at 35 l/hr for C1 and C2, respectively. Friction factor DIW in C1 and C2 decreased with the volumetric flow rate increases, reaching minimum values of 0.04 and 0.25 respectively. Pressure drop of DIW increased linearly with flow rate reaching maximum values of 81.4 and 4.31 for C1 and C2 respectively. This in turn leads to reduced TCTHE length and size leading to a decrease in the construction cost of the heat exchanger.
format Article
id doaj-art-018f64b39a8b48ef8e17b21743bb5d29
institution Kabale University
issn 2078-8665
2411-7986
language English
publishDate 2023-08-01
publisher University of Baghdad, College of Science for Women
record_format Article
series مجلة بغداد للعلوم
spelling doaj-art-018f64b39a8b48ef8e17b21743bb5d292025-08-20T03:34:17ZengUniversity of Baghdad, College of Science for Womenمجلة بغداد للعلوم2078-86652411-79862023-08-0120410.21123/bsj.2023.7584Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40Huda Majid Hasen 0Department of Chemistry, College of Science, University of Thi-Qar, Thi-Qar, Iraq This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670 mm. Nusselt number, overall heat transfer coefficient, convective heat transfer coefficient (CHTC), friction factor and pressure drop were measured from the obtained experimental results and plotted in graphs against Reynold number and volumetric flow rate of water. These parameters appeared good results in the cooling process. Nusselt numbers increased linearly with DIW flow rate for both C1 and C2 reaching maximum values of 38.25 and 14.64 respectively. CHTC increased linearly with the DIW flow rate for both C1 and C2 reaching maximum values of 2934.3 and 871.7 respectively. Overall heat transfer coefficient of DIW reached maximum values of 296.36 and 251.4 at 35 l/hr for C1 and C2, respectively. Friction factor DIW in C1 and C2 decreased with the volumetric flow rate increases, reaching minimum values of 0.04 and 0.25 respectively. Pressure drop of DIW increased linearly with flow rate reaching maximum values of 81.4 and 4.31 for C1 and C2 respectively. This in turn leads to reduced TCTHE length and size leading to a decrease in the construction cost of the heat exchanger. https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/7584Friction factor, Nusselt number, Overall heat transfer coefficient, Pressure drop, TCTHE, Triple concentric tube heat exchanger.
spellingShingle Huda Majid Hasen
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
مجلة بغداد للعلوم
Friction factor, Nusselt number, Overall heat transfer coefficient, Pressure drop, TCTHE, Triple concentric tube heat exchanger.
title Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
title_full Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
title_fullStr Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
title_full_unstemmed Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
title_short Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
title_sort performance evaluation of a triple concentric tube heat exchanger using deionized water and oil 40
topic Friction factor, Nusselt number, Overall heat transfer coefficient, Pressure drop, TCTHE, Triple concentric tube heat exchanger.
url https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/7584
work_keys_str_mv AT hudamajidhasen performanceevaluationofatripleconcentrictubeheatexchangerusingdeionizedwaterandoil40