Measuring. Monitoring. Management. Control
Background. The purpose of the study is to develop and investigate a minor-error amplitude detector for converting the amplitude of a sine wave voltage into the direct current voltage. Materials and methods. The implicit method for calculating the root mean square (rms) values of alternating volta...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penza State University Publishing House
2024-12-01
|
Series: | Измерение, мониторинг, управление, контроль |
Subjects: | |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background. The purpose of the study is to develop and investigate a minor-error amplitude detector for
converting the amplitude of a sine wave voltage into the direct current voltage. Materials and methods. The implicit
method for calculating the root mean square (rms) values of alternating voltage has been implemented to investigate the
amplitude detector. Results. A block diagram for the amplitude detector along with the research methodology and outcomes
are presented. Provided the sinusoidal voltage waveform is with 5 V to 10 V amplitude and 100 Hz to 1 MHz
frequency, the relative error in converting the rms voltage value falls short of ± 2 %, and the relative error in converting the
voltage amplitude being ± 1.5 %. Conclusions. The feasibility of using an amplitude detector that implements the implicit
method for calculating the rms values of alternating voltage to develop means for measuring resonant electrical circuit
parameters has been substantiated. |
---|---|
ISSN: | 2307-5538 |