Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies

While planning medical care, health care workers must consider the body temperature changes as measured by the mothers on most occasions. We evaluated the reliability of three different temperature measurement methods when they were used by the mothers by comparing with the measurements taken...

Full description

Saved in:
Bibliographic Details
Main Authors: Oge Cultu, Inci Yildirim, Mehmet Ceyhan, Ayşe Korkmaz, Murat Yurdakök, Ergun Karaağaoğlu, Gülten Seçmeer
Format: Article
Language:English
Published: Hacettepe University Institute of Child Health 2008-08-01
Series:The Turkish Journal of Pediatrics
Online Access:https://turkjpediatr.org/article/view/2446
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849705871948382208
author Oge Cultu
Inci Yildirim
Mehmet Ceyhan
Ayşe Korkmaz
Murat Yurdakök
Ergun Karaağaoğlu
Gülten Seçmeer
author_facet Oge Cultu
Inci Yildirim
Mehmet Ceyhan
Ayşe Korkmaz
Murat Yurdakök
Ergun Karaağaoğlu
Gülten Seçmeer
author_sort Oge Cultu
collection DOAJ
description While planning medical care, health care workers must consider the body temperature changes as measured by the mothers on most occasions. We evaluated the reliability of three different temperature measurement methods when they were used by the mothers by comparing with the measurements taken by the pediatrician. In this prospective study, body temperatures of 50 healthy newborns during their 2nd day of life were measured by mothers and one physician with mercury-in-glass (MG), digital mercury (DM) and infrared tympanic membrane thermometers (ITMT). Measurements by the mothers and the physician were correlated for the three different methods. The effects of the educational level of the mothers and the presence of children at home on the reliability and the number of differences > or = 0.5 degrees C were also evaluated for each of the methods. In comparing the measurements by the mothers and the pediatrician, correlation coefficient was 0.12 in MG thermometer readings, 0.23 in DM thermometer readings and 0.78 in ITMT readings, meaning that tympanic measurements by the mothers and the pediatricians were more correlated (p < 0.0001). The means and ranges of absolute differences of MG, DM, and tympanic thermometer measurements were 0.43 +/- 0.42, 0-1.7; 0.36 +/- 0.45, 0-2.2; and 0.13 +/- 0.12, 0-0.7 degrees C, respectively. The number of measurements with an absolute difference > or = 0.5 degrees C was 17 in MG readings, 11 in DM readings, and 1 in ITMT readings, The educational level of the mothers and the presence of children at home had no effect on the correlations. The intraclass coefficient for the three sets of measurements by the pediatricians was 0.91. Body temperature measurements in newborn babies as taken by their mothers were more correlated with the readings by the pediatricians when the ITMT was used. Tympanic thermometers seem to be useful for the mothers of any educational level and are independent of having experience with a previous child. The ease of use and short calibration time for reading are also advantageous for these thermometers.
format Article
id doaj-art-002732f09e0e456cb2ebe94ffee5ccbd
institution DOAJ
issn 0041-4301
2791-6421
language English
publishDate 2008-08-01
publisher Hacettepe University Institute of Child Health
record_format Article
series The Turkish Journal of Pediatrics
spelling doaj-art-002732f09e0e456cb2ebe94ffee5ccbd2025-08-20T03:16:22ZengHacettepe University Institute of Child HealthThe Turkish Journal of Pediatrics0041-43012791-64212008-08-01504Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babiesOge Cultu0Inci YildirimMehmet CeyhanAyşe KorkmazMurat YurdakökErgun KaraağaoğluGülten SeçmeerDepartment of Pediatrics, Hacettepe University Faculty of Medicine, Ankara, Turkey. While planning medical care, health care workers must consider the body temperature changes as measured by the mothers on most occasions. We evaluated the reliability of three different temperature measurement methods when they were used by the mothers by comparing with the measurements taken by the pediatrician. In this prospective study, body temperatures of 50 healthy newborns during their 2nd day of life were measured by mothers and one physician with mercury-in-glass (MG), digital mercury (DM) and infrared tympanic membrane thermometers (ITMT). Measurements by the mothers and the physician were correlated for the three different methods. The effects of the educational level of the mothers and the presence of children at home on the reliability and the number of differences > or = 0.5 degrees C were also evaluated for each of the methods. In comparing the measurements by the mothers and the pediatrician, correlation coefficient was 0.12 in MG thermometer readings, 0.23 in DM thermometer readings and 0.78 in ITMT readings, meaning that tympanic measurements by the mothers and the pediatricians were more correlated (p < 0.0001). The means and ranges of absolute differences of MG, DM, and tympanic thermometer measurements were 0.43 +/- 0.42, 0-1.7; 0.36 +/- 0.45, 0-2.2; and 0.13 +/- 0.12, 0-0.7 degrees C, respectively. The number of measurements with an absolute difference > or = 0.5 degrees C was 17 in MG readings, 11 in DM readings, and 1 in ITMT readings, The educational level of the mothers and the presence of children at home had no effect on the correlations. The intraclass coefficient for the three sets of measurements by the pediatricians was 0.91. Body temperature measurements in newborn babies as taken by their mothers were more correlated with the readings by the pediatricians when the ITMT was used. Tympanic thermometers seem to be useful for the mothers of any educational level and are independent of having experience with a previous child. The ease of use and short calibration time for reading are also advantageous for these thermometers. https://turkjpediatr.org/article/view/2446
spellingShingle Oge Cultu
Inci Yildirim
Mehmet Ceyhan
Ayşe Korkmaz
Murat Yurdakök
Ergun Karaağaoğlu
Gülten Seçmeer
Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
The Turkish Journal of Pediatrics
title Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
title_full Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
title_fullStr Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
title_full_unstemmed Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
title_short Comparing body temperature measurements by mothers and physicians using mercury-in-glass, digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
title_sort comparing body temperature measurements by mothers and physicians using mercury in glass digital mercury and infrared tympanic membrane thermometers in healthy newborn babies
url https://turkjpediatr.org/article/view/2446
work_keys_str_mv AT ogecultu comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies
AT inciyildirim comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies
AT mehmetceyhan comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies
AT aysekorkmaz comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies
AT muratyurdakok comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies
AT ergunkaraagaoglu comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies
AT gultensecmeer comparingbodytemperaturemeasurementsbymothersandphysiciansusingmercuryinglassdigitalmercuryandinfraredtympanicmembranethermometersinhealthynewbornbabies