Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars

The use of steel bars as reinforcement is not preferred in some concrete structures because steel causes corrosion or electric magnetic field problems. One of the best alternatives to steel bars is carbon fibre-reinforced polymer (CFRP) bars. The experimental program consisted of 18 reinforced recta...

Full description

Saved in:
Bibliographic Details
Main Authors: Zrar Sedeeq Othman, Ahmed Heidayet Mohammad
Format: Article
Language:English
Published: Wiley 2019-01-01
Series:Advances in Civil Engineering
Online Access:http://dx.doi.org/10.1155/2019/1769212
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832563744978239488
author Zrar Sedeeq Othman
Ahmed Heidayet Mohammad
author_facet Zrar Sedeeq Othman
Ahmed Heidayet Mohammad
author_sort Zrar Sedeeq Othman
collection DOAJ
description The use of steel bars as reinforcement is not preferred in some concrete structures because steel causes corrosion or electric magnetic field problems. One of the best alternatives to steel bars is carbon fibre-reinforced polymer (CFRP) bars. The experimental program consisted of 18 reinforced rectangular concrete columns under different eccentric loadings. Out of the 18 columns, 15 were reinforced with CFRP longitudinal rebars and ties and 3 were reinforced with conventional steel rebars and ties as reference columns. The following parameters were included in this study: the replacement of steel with CFRP bars, eccentricity of load, longitudinal reinforcement ratios, and tie spacing. Test results in terms of load-strain, load-mid height deflection curves, and crack patterns showed that the column reinforced with CFRP bars behaved similarly to the concrete column reinforced with conventional steel bars with a slight difference in axial and flexural capacity. The increment in CFRP longitudinal reinforcement ratios from 1.4% to 2.0% and 3.6% reasonably increased the maximum carrying capacity for different eccentricities used herein. The axial ratios of experimental to theoretical results (PExp./PTheor.) were determined for specimens in the present work and those from previous studies to assess the efficiency of the theoretical models.
format Article
id doaj-art-ff7de28c1ab145119c05eae9304b35e1
institution Kabale University
issn 1687-8086
1687-8094
language English
publishDate 2019-01-01
publisher Wiley
record_format Article
series Advances in Civil Engineering
spelling doaj-art-ff7de28c1ab145119c05eae9304b35e12025-02-03T01:12:50ZengWileyAdvances in Civil Engineering1687-80861687-80942019-01-01201910.1155/2019/17692121769212Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer BarsZrar Sedeeq Othman0Ahmed Heidayet Mohammad1Ph. D. Student, Civil Engineering Department, Salahaddin University-Erbil, Erbil, IraqAssistant Professor, Civil Engineering Department, Salahaddin University-Erbil, Erbil, IraqThe use of steel bars as reinforcement is not preferred in some concrete structures because steel causes corrosion or electric magnetic field problems. One of the best alternatives to steel bars is carbon fibre-reinforced polymer (CFRP) bars. The experimental program consisted of 18 reinforced rectangular concrete columns under different eccentric loadings. Out of the 18 columns, 15 were reinforced with CFRP longitudinal rebars and ties and 3 were reinforced with conventional steel rebars and ties as reference columns. The following parameters were included in this study: the replacement of steel with CFRP bars, eccentricity of load, longitudinal reinforcement ratios, and tie spacing. Test results in terms of load-strain, load-mid height deflection curves, and crack patterns showed that the column reinforced with CFRP bars behaved similarly to the concrete column reinforced with conventional steel bars with a slight difference in axial and flexural capacity. The increment in CFRP longitudinal reinforcement ratios from 1.4% to 2.0% and 3.6% reasonably increased the maximum carrying capacity for different eccentricities used herein. The axial ratios of experimental to theoretical results (PExp./PTheor.) were determined for specimens in the present work and those from previous studies to assess the efficiency of the theoretical models.http://dx.doi.org/10.1155/2019/1769212
spellingShingle Zrar Sedeeq Othman
Ahmed Heidayet Mohammad
Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars
Advances in Civil Engineering
title Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars
title_full Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars
title_fullStr Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars
title_full_unstemmed Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars
title_short Behaviour of Eccentric Concrete Columns Reinforced with Carbon Fibre-Reinforced Polymer Bars
title_sort behaviour of eccentric concrete columns reinforced with carbon fibre reinforced polymer bars
url http://dx.doi.org/10.1155/2019/1769212
work_keys_str_mv AT zrarsedeeqothman behaviourofeccentricconcretecolumnsreinforcedwithcarbonfibrereinforcedpolymerbars
AT ahmedheidayetmohammad behaviourofeccentricconcretecolumnsreinforcedwithcarbonfibrereinforcedpolymerbars