An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
In museum exhibition halls, two-dimensional artworks are displayed usually on vertical surfaces. The uniformity of illuminance distribution in the exhibition area is significant. The control of the illuminance distribution depends on the dimensions of the exhibition hall, the size and location of t...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Alanya Üniversitesi
2022-05-01
|
| Series: | Proceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA |
| Subjects: | |
| Online Access: | https://journal.iccaua.com/jiccaua/article/view/8 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849393810640994304 |
|---|---|
| author | Sezgi Kalelioğlu Leyla Dokuzer Öztürk |
| author_facet | Sezgi Kalelioğlu Leyla Dokuzer Öztürk |
| author_sort | Sezgi Kalelioğlu |
| collection | DOAJ |
| description |
In museum exhibition halls, two-dimensional artworks are displayed usually on vertical surfaces. The uniformity of illuminance distribution in the exhibition area is significant. The control of the illuminance distribution depends on the dimensions of the exhibition hall, the size and location of the exhibition area, and the type, luminous intensity distribution, and position of the luminaire. This study aims to identify the optimal conditions to acquire the targeted illuminance uniformity. For this purpose, sixteen situations were composed concerning four different heights of the exhibition hall and four exhibition areas of various sizes. The luminaires used in the investigation were small and linear with symmetrical and asymmetrical luminous intensity distributions. The position of each luminaire was arranged in the mentioned sixteen situations to obtain optimum conditions. The comparison of the results referred to the energy consumption.
|
| format | Article |
| id | doaj-art-db4b28fd8b9d417e9ccd34903ad8e4fa |
| institution | Kabale University |
| issn | 3023-7009 |
| language | English |
| publishDate | 2022-05-01 |
| publisher | Alanya Üniversitesi |
| record_format | Article |
| series | Proceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA |
| spelling | doaj-art-db4b28fd8b9d417e9ccd34903ad8e4fa2025-08-20T03:40:17ZengAlanya ÜniversitesiProceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA3023-70092022-05-015110.38027/ICCAUA2022EN0050An Approach to Control the Illuminance Distribution on Vertical Display SurfacesSezgi Kalelioğlu0Leyla Dokuzer Öztürk1Yıldız Technical University, Faculty of Architecture, Department of Architecture, Istanbul, TurkeyYıldız Technical University, Faculty of Architecture, Department of Architecture, Istanbul, Turkey In museum exhibition halls, two-dimensional artworks are displayed usually on vertical surfaces. The uniformity of illuminance distribution in the exhibition area is significant. The control of the illuminance distribution depends on the dimensions of the exhibition hall, the size and location of the exhibition area, and the type, luminous intensity distribution, and position of the luminaire. This study aims to identify the optimal conditions to acquire the targeted illuminance uniformity. For this purpose, sixteen situations were composed concerning four different heights of the exhibition hall and four exhibition areas of various sizes. The luminaires used in the investigation were small and linear with symmetrical and asymmetrical luminous intensity distributions. The position of each luminaire was arranged in the mentioned sixteen situations to obtain optimum conditions. The comparison of the results referred to the energy consumption. https://journal.iccaua.com/jiccaua/article/view/8Vertical DisplayIlluminance UniformityEnergy ConsumptionLuminaire Features |
| spellingShingle | Sezgi Kalelioğlu Leyla Dokuzer Öztürk An Approach to Control the Illuminance Distribution on Vertical Display Surfaces Proceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA Vertical Display Illuminance Uniformity Energy Consumption Luminaire Features |
| title | An Approach to Control the Illuminance Distribution on Vertical Display Surfaces |
| title_full | An Approach to Control the Illuminance Distribution on Vertical Display Surfaces |
| title_fullStr | An Approach to Control the Illuminance Distribution on Vertical Display Surfaces |
| title_full_unstemmed | An Approach to Control the Illuminance Distribution on Vertical Display Surfaces |
| title_short | An Approach to Control the Illuminance Distribution on Vertical Display Surfaces |
| title_sort | approach to control the illuminance distribution on vertical display surfaces |
| topic | Vertical Display Illuminance Uniformity Energy Consumption Luminaire Features |
| url | https://journal.iccaua.com/jiccaua/article/view/8 |
| work_keys_str_mv | AT sezgikalelioglu anapproachtocontroltheilluminancedistributiononverticaldisplaysurfaces AT leyladokuzerozturk anapproachtocontroltheilluminancedistributiononverticaldisplaysurfaces AT sezgikalelioglu approachtocontroltheilluminancedistributiononverticaldisplaysurfaces AT leyladokuzerozturk approachtocontroltheilluminancedistributiononverticaldisplaysurfaces |