An Approach to Control the Illuminance Distribution on Vertical Display Surfaces

In museum exhibition halls, two-dimensional artworks are displayed usually on vertical surfaces. The uniformity of illuminance distribution in the exhibition area is significant. The control of the illuminance distribution depends on the dimensions of the exhibition hall, the size and location of t...

Full description

Saved in:
Bibliographic Details
Main Authors: Sezgi Kalelioğlu, Leyla Dokuzer Öztürk
Format: Article
Language:English
Published: Alanya Üniversitesi 2022-05-01
Series:Proceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA
Subjects:
Online Access:https://journal.iccaua.com/jiccaua/article/view/8
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849393810640994304
author Sezgi Kalelioğlu
Leyla Dokuzer Öztürk
author_facet Sezgi Kalelioğlu
Leyla Dokuzer Öztürk
author_sort Sezgi Kalelioğlu
collection DOAJ
description In museum exhibition halls, two-dimensional artworks are displayed usually on vertical surfaces. The uniformity of illuminance distribution in the exhibition area is significant. The control of the illuminance distribution depends on the dimensions of the exhibition hall, the size and location of the exhibition area, and the type, luminous intensity distribution, and position of the luminaire. This study aims to identify the optimal conditions to acquire the targeted illuminance uniformity. For this purpose, sixteen situations were composed concerning four different heights of the exhibition hall and four exhibition areas of various sizes. The luminaires used in the investigation were small and linear with symmetrical and asymmetrical luminous intensity distributions. The position of each luminaire was arranged in the mentioned sixteen situations to obtain optimum conditions. The comparison of the results referred to the energy consumption.
format Article
id doaj-art-db4b28fd8b9d417e9ccd34903ad8e4fa
institution Kabale University
issn 3023-7009
language English
publishDate 2022-05-01
publisher Alanya Üniversitesi
record_format Article
series Proceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA
spelling doaj-art-db4b28fd8b9d417e9ccd34903ad8e4fa2025-08-20T03:40:17ZengAlanya ÜniversitesiProceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA3023-70092022-05-015110.38027/ICCAUA2022EN0050An Approach to Control the Illuminance Distribution on Vertical Display SurfacesSezgi Kalelioğlu0Leyla Dokuzer Öztürk1Yıldız Technical University, Faculty of Architecture, Department of Architecture, Istanbul, TurkeyYıldız Technical University, Faculty of Architecture, Department of Architecture, Istanbul, Turkey In museum exhibition halls, two-dimensional artworks are displayed usually on vertical surfaces. The uniformity of illuminance distribution in the exhibition area is significant. The control of the illuminance distribution depends on the dimensions of the exhibition hall, the size and location of the exhibition area, and the type, luminous intensity distribution, and position of the luminaire. This study aims to identify the optimal conditions to acquire the targeted illuminance uniformity. For this purpose, sixteen situations were composed concerning four different heights of the exhibition hall and four exhibition areas of various sizes. The luminaires used in the investigation were small and linear with symmetrical and asymmetrical luminous intensity distributions. The position of each luminaire was arranged in the mentioned sixteen situations to obtain optimum conditions. The comparison of the results referred to the energy consumption. https://journal.iccaua.com/jiccaua/article/view/8Vertical DisplayIlluminance UniformityEnergy ConsumptionLuminaire Features
spellingShingle Sezgi Kalelioğlu
Leyla Dokuzer Öztürk
An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
Proceedings of the International Conference of Contemporary Affairs in Architecture and Urbanism-ICCAUA
Vertical Display
Illuminance Uniformity
Energy Consumption
Luminaire Features
title An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
title_full An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
title_fullStr An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
title_full_unstemmed An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
title_short An Approach to Control the Illuminance Distribution on Vertical Display Surfaces
title_sort approach to control the illuminance distribution on vertical display surfaces
topic Vertical Display
Illuminance Uniformity
Energy Consumption
Luminaire Features
url https://journal.iccaua.com/jiccaua/article/view/8
work_keys_str_mv AT sezgikalelioglu anapproachtocontroltheilluminancedistributiononverticaldisplaysurfaces
AT leyladokuzerozturk anapproachtocontroltheilluminancedistributiononverticaldisplaysurfaces
AT sezgikalelioglu approachtocontroltheilluminancedistributiononverticaldisplaysurfaces
AT leyladokuzerozturk approachtocontroltheilluminancedistributiononverticaldisplaysurfaces