Test Method for Ammonia Injection Optimization of SCR Denitrification System Based on CFD Simulation Calculation
In this paper, a method of simulation calculation with computational fluid dynamics (CFD) is presented to precisely adjust the ammonia injection grid valve by introducing tracer gases into the denitrification system. Through full-scale modeling of the SCR system, and by replacing the original flue g...