A case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods agai...

Full description

Saved in:
Bibliographic Details
Main Authors: Krzysztof Zakowski, Michal Narozny, Kazimierz Darowicki
Format: Article
Language:English
Published: Riga Technical University Press 2015-03-01
Series:The Baltic Journal of Road and Bridge Engineering
Subjects:
Online Access:https://bjrbe-journals.rtu.lv/article/view/3411
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system against stray currents was proposed and designed at the Department of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology. Coupon technique measurements and potential measurements were performed to verify the effectiveness of the protection system.