Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis
Comparison of bioradiolocation and standard respiratory plethysmography signals during simultaneous registration of different types of the human breathing movements is performed in both time and frequency domains. For all couples of synchronized signals corresponding to bioradiolocation and respirat...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2013-01-01
|
| Series: | International Journal of Antennas and Propagation |
| Online Access: | http://dx.doi.org/10.1155/2013/410692 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849308744212545536 |
|---|---|
| author | Maksim Alekhin Lesya Anishchenko Alexander Tataraidze Sergey Ivashov Vladimir Parashin Alexander Dyachenko |
| author_facet | Maksim Alekhin Lesya Anishchenko Alexander Tataraidze Sergey Ivashov Vladimir Parashin Alexander Dyachenko |
| author_sort | Maksim Alekhin |
| collection | DOAJ |
| description | Comparison of bioradiolocation and standard respiratory plethysmography signals during simultaneous registration of different types of the human breathing movements is performed in both time and frequency domains. For all couples of synchronized signals corresponding to bioradiolocation and respiratory plethysmography methods, the cross-correlation and spectral functions are calculated, and estimates of their generalized characteristics are defined. The obtained results consider bioradiolocation to be a reliable remote sensing technique for noncontact monitoring of breathing pattern in medical applications. |
| format | Article |
| id | doaj-art-1a6d45f6182d48c19cc232472d638f38 |
| institution | Kabale University |
| issn | 1687-5869 1687-5877 |
| language | English |
| publishDate | 2013-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | International Journal of Antennas and Propagation |
| spelling | doaj-art-1a6d45f6182d48c19cc232472d638f382025-08-20T03:54:23ZengWileyInternational Journal of Antennas and Propagation1687-58691687-58772013-01-01201310.1155/2013/410692410692Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral AnalysisMaksim Alekhin0Lesya Anishchenko1Alexander Tataraidze2Sergey Ivashov3Vladimir Parashin4Alexander Dyachenko5Remote Sensing Laboratory, Bauman Moscow State Technical University, 2nd Baumanskaya 5, Moscow 105005, RussiaRemote Sensing Laboratory, Bauman Moscow State Technical University, 2nd Baumanskaya 5, Moscow 105005, RussiaRemote Sensing Laboratory, Bauman Moscow State Technical University, 2nd Baumanskaya 5, Moscow 105005, RussiaRemote Sensing Laboratory, Bauman Moscow State Technical University, 2nd Baumanskaya 5, Moscow 105005, RussiaDepartment of Biomedical Engineering, Bauman Moscow State Technical University, 2nd Baumanskaya 5, Moscow 105005, RussiaDepartment of Ecological and Medical Problems, Prokhorov General Physics Institute, Russian Academy of Sciences, Vavilova 38, Moscow 119991, RussiaComparison of bioradiolocation and standard respiratory plethysmography signals during simultaneous registration of different types of the human breathing movements is performed in both time and frequency domains. For all couples of synchronized signals corresponding to bioradiolocation and respiratory plethysmography methods, the cross-correlation and spectral functions are calculated, and estimates of their generalized characteristics are defined. The obtained results consider bioradiolocation to be a reliable remote sensing technique for noncontact monitoring of breathing pattern in medical applications.http://dx.doi.org/10.1155/2013/410692 |
| spellingShingle | Maksim Alekhin Lesya Anishchenko Alexander Tataraidze Sergey Ivashov Vladimir Parashin Alexander Dyachenko Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis International Journal of Antennas and Propagation |
| title | Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis |
| title_full | Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis |
| title_fullStr | Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis |
| title_full_unstemmed | Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis |
| title_short | Comparison of Bioradiolocation and Respiratory Plethysmography Signals in Time and Frequency Domains on the Base of Cross-Correlation and Spectral Analysis |
| title_sort | comparison of bioradiolocation and respiratory plethysmography signals in time and frequency domains on the base of cross correlation and spectral analysis |
| url | http://dx.doi.org/10.1155/2013/410692 |
| work_keys_str_mv | AT maksimalekhin comparisonofbioradiolocationandrespiratoryplethysmographysignalsintimeandfrequencydomainsonthebaseofcrosscorrelationandspectralanalysis AT lesyaanishchenko comparisonofbioradiolocationandrespiratoryplethysmographysignalsintimeandfrequencydomainsonthebaseofcrosscorrelationandspectralanalysis AT alexandertataraidze comparisonofbioradiolocationandrespiratoryplethysmographysignalsintimeandfrequencydomainsonthebaseofcrosscorrelationandspectralanalysis AT sergeyivashov comparisonofbioradiolocationandrespiratoryplethysmographysignalsintimeandfrequencydomainsonthebaseofcrosscorrelationandspectralanalysis AT vladimirparashin comparisonofbioradiolocationandrespiratoryplethysmographysignalsintimeandfrequencydomainsonthebaseofcrosscorrelationandspectralanalysis AT alexanderdyachenko comparisonofbioradiolocationandrespiratoryplethysmographysignalsintimeandfrequencydomainsonthebaseofcrosscorrelationandspectralanalysis |